Bit Switches - 3
• Do not adjust a bit switch or use a setting that is described as "Not used", as this may cause the
machine to malfunction or to operate in a manner that is not accepted by local regulations. Such
bits are for use only in other areas, such as Japan.
Default settings for bit switches are not listed in this manual. Refer to the System Parameter List printed by
the machine.
Communication Switches
Communication Switch 00 (SP No. 1-104-001)
No
Function
Comments
0-1
Compression modes available in receive mode
These bits determine the compression
capabilities to be declared in phase B
(handshaking) of the T.30 protocol.
Bit 1
Bit 0
Modes
0
0
MH only
0
1
MH/MR
1
0
MH/MR/MMR
1
1
MH/MR/MMR/JBIG
2-3
Compression modes available in transmit mode
These bits determine the compression
capabilities to be used in the
transmission and to be declared in phase
B (handshaking) of the T.30 protocol.
Bit 3
Bit 2
Modes
0
0
MH only
0
1
MH/MR
1
0
MH/MR/MMR
1
1
MH/MR/MMR/JBIG
4
Not used
Do not change the settings.
5
JBIG compression method: Reception
0: Only basic supported
1: Basic and optional both supported
Change the setting when communication
problems occur using JBIG compression.
Bit Switches - 3
123
Summary of Contents for Type M12
Page 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Page 2: ......
Page 10: ...8...
Page 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Page 50: ...2 Replacement and Adjustment 48...
Page 84: ...3 Troubleshooting 82...
Page 218: ...5 Detailed Section Descriptions 216...
Page 226: ...MEMO 224 EN...