Address
Function
Unit
Remarks
680572
Acceptable ringing signal frequency:
range 1, upper limit
1000/ N
(Hz).
SP2-103-003 (parameter
02).
680573
Acceptable ringing signal frequency:
range 1, lower limit
SP2-103-004 (parameter
03).
680574
Acceptable ringing signal frequency:
range 2, upper limit
SP2-103-005 (parameter
04).
680575
Acceptable ringing signal frequency:
range 2, lower limit
SP2-103-006 (parameter
05).
680576
Number of rings until a call is detected
1
SP2-103-007 (parameter
06).
The setting must not be zero.
680577
Minimum required length of the first
ring
20 ms
See Note 4.
SP2-103-008 (parameter
07).
680578
Minimum required length of the second
and subsequent rings
20 ms
SP2-103-009 (parameter
08).
680579
Ringing signal detection reset time
(LOW)
20 ms
SP2-103-010 (parameter
09).
68057A
Ringing signal detection reset time
(HIGH)
SP2-103-011 (parameter
10).
68057B
to
680580
Not used
-
Do not change the settings.
680581
Interval between dialing the last digit
and switching the Oh relay over to the
external telephone when dialing from
the operation panel in handset mode.
20 ms
Factory setting: 500 ms
NCU Parameters
169
Summary of Contents for Type M12
Page 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Page 2: ......
Page 10: ...8...
Page 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Page 50: ...2 Replacement and Adjustment 48...
Page 84: ...3 Troubleshooting 82...
Page 218: ...5 Detailed Section Descriptions 216...
Page 226: ...MEMO 224 EN...