4-7
Modem types available for reception
The setting of these bits is used to inform the transmitting terminal of the available modem type
for the machine in receive mode.
If V.34 is not selected, V.8 protocol must be disabled manually.
Cross reference
V.8 protocol on/off - G3 switch 03, bit 2
Bit 7
Bit 6
Bit 5
Bit 4
Types
0
0
0
1
V.27ter
0
0
1
0
V.27ter, V.29
0
0
1
1
V.27ter, V.29, V.33
0
1
0
0
V.27ter, V.29, V.17
0
1
0
1
V.27ter, V.29, V.17, V.34
Other settings - Not used
G3 Switch 07 (SP No. 1-105-008)
No
Function
Comments
0-1
PSTN cable equalizer
(tx mode: Internal)
Use a higher setting if there is signal loss at
higher frequencies because of the length of
wire between the modem and the telephone
exchange.
Use the dedicated transmission parameters for
specific receivers.
Also, try using the cable equalizer if one or
more of the following symptoms occurs.
Communication error
Modem rate fallback occurs frequently.
• This setting is not effective in V.34
communications.
Bit 1
Bit 0
Setting
0
0
None
0
1
Low
1
0
Medium
1
1
High
4. Service Tables
138
Summary of Contents for Type M12
Page 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Page 2: ......
Page 10: ...8...
Page 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Page 50: ...2 Replacement and Adjustment 48...
Page 84: ...3 Troubleshooting 82...
Page 218: ...5 Detailed Section Descriptions 216...
Page 226: ...MEMO 224 EN...