Address
Function
Unit
Remarks
680501
Line current detection time
20 ms
Line current detection is
disabled.
Line current is not detected if
680501 contains FF.
680502
Line current wait time
680503
Line current drop detect time
680504
PSTN dial tone frequency upper limit
(high byte)
Hz (BCD)
If both addresses contain
FF(H), tone detection is
disabled.
680505
PSTN dial tone frequency upper limit
(low byte)
680506
PSTN dial tone frequency lower limit
(high byte)
Hz (BCD)
If both addresses contain
FF(H), tone detection is
disabled.
680507
PSTN dial tone frequency lower limit
(low byte)
680508
PSTN dial tone detection time
20 ms
If 680508 contains FF(H),
the machine pauses for the
pause time (address
68050D / 68050E).
Italy: See Note 2.
680509
PSTN dial tone reset time (LOW)
68050A
PSTN dial tone reset time (HIGH)
68050B
PSTN dial tone continuous tone time
68050C
PSTN dial tone permissible drop time
68050D
PSTN wait interval (LOW)
-
68050E
PSTN wait interval (HIGH)
68050F
PSTN ring-back tone detection time
20 ms
Detection is disabled if this
contains FF.
680510
PSTN ring-back tone off detection time
20 ms
-
680511
PSTN detection time for silent period
after ring-back tone detected (LOW)
20 ms
-
680512
PSTN detection time for silent period
after ring-back tone detected (HIGH)
20 ms
-
4. Service Tables
162
Summary of Contents for Type M12
Page 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Page 2: ......
Page 10: ...8...
Page 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Page 50: ...2 Replacement and Adjustment 48...
Page 84: ...3 Troubleshooting 82...
Page 218: ...5 Detailed Section Descriptions 216...
Page 226: ...MEMO 224 EN...