Procedure
1.
Open the center top and center front covers of the printer.
2.
Use a toner-certified vacuum cleaner to clean the following:
v
Input area
v
End-of-forms sensor
v
Forms guide
v
Splicing table and attached static brush
3.
Cleaning the Universal Forms Control sensor:
Clean the upper and lower UFC
sensors follows:
a.
Rotate open the UFC sensor assembly
(1)
.
b.
Dampen a lint free cloth with distilled water.
Note:
Do not use solvents as they will damage the sensors.
c.
Gently wipe the upper
(2)
and lower
(3)
UFC sensors.
d.
Rotate closed the UFC sensor assembly.
DANGER
hcsf0115
To vacuum toner, use only an approved vacuum cleaner.
<1-15>
Chapter 7. Cleaning and Servicing the printer
265