Open the upper mark sensor assembly (
7
) by raising the upper mark sensor
assembly lever (
8
).
c.
Align the opening of the scale alignment guide (
11
) with the mark (
2
) using
the
Forms Feed Forward
and
Forms Feed Reverse
buttons (
3
). While in
sensor adjustment mode these buttons will move the forms very slowly. Use
Forms Feed Forward/Reverse with the sensor closed until the lowest value
is displayed.
d.
Close the upper mark sensor assembly (
7
).
e.
Rotate the mark sensor positioning knob (
6
) until the brightness reading is
at it's lowest point.
f.
Press and hold the orange
UP
button until the displayed numbers blink
twice then release the
UP
button. The display will alternate between a
brightness (
1
) / mark threshold (
2
) reading similar to this
and this display
.
5.
Adjust the sensor to read the forms background brightness.
202
Operating the InfoPrint 4100
Summary of Contents for InfoPrint 4100 TD3
Page 1: ...Operating the InfoPrint 4100 InfoPrint 4100 Models TS2 TD3 4 TS3 and TD5 6 S550 1298 02...
Page 2: ......
Page 3: ...Operating the InfoPrint 4100 InfoPrint 4100 Models TS2 TD3 4 TS3 and TD5 6 S550 1298 02...
Page 8: ...vi Operating the InfoPrint 4100...
Page 12: ...x Operating the InfoPrint 4100...
Page 14: ...xii Operating the InfoPrint 4100...
Page 60: ...46 Operating the InfoPrint 4100...
Page 268: ...254 Operating the InfoPrint 4100...
Page 360: ...346 Operating the InfoPrint 4100...
Page 407: ...Administrator panel Chapter 8 Help topics for the InfoPrint 4100 operator console 393...
Page 408: ...394 Operating the InfoPrint 4100...
Page 461: ......
Page 462: ...Program Number 5765 G79 5765 G74 Printed in USA S550 1298 02...