Chapter 3, “Operating the printer,” on page 47
Cleaning the developer area
About this task
Procedure:
Do this procedure to clean the developer area. Use this procedure when your
printer does not have the customer-replaceable corona wires installed.
Procedure
1.
Open the right front cover of the printer.
2.
To clean each corona (preclean, precharge, and charge), do the following:
Important:
There is no device to prevent you from pulling out the coronas. Be
careful not to break the thin wires and tiny retractor springs inside the corona.
a.
Pull each white corona (the shaded areas in the illustration) toward you
until it is
almost
out of its track. A brush inside the corona housing cleans
the corona as you pull it out and then push it back in.
b.
Gently push each corona back into place. Make sure that the corona is
pushed in completely.
3.
Use a cloth or paper towel to wipe away any paper dust, toner, or other debris
from the developer area.
IC3U0014
Figure 94. Corona locations
Chapter 7. Cleaning and Servicing the printer
257
Summary of Contents for InfoPrint 4100 TD3
Page 1: ...Operating the InfoPrint 4100 InfoPrint 4100 Models TS2 TD3 4 TS3 and TD5 6 S550 1298 02...
Page 2: ......
Page 3: ...Operating the InfoPrint 4100 InfoPrint 4100 Models TS2 TD3 4 TS3 and TD5 6 S550 1298 02...
Page 8: ...vi Operating the InfoPrint 4100...
Page 12: ...x Operating the InfoPrint 4100...
Page 14: ...xii Operating the InfoPrint 4100...
Page 60: ...46 Operating the InfoPrint 4100...
Page 268: ...254 Operating the InfoPrint 4100...
Page 360: ...346 Operating the InfoPrint 4100...
Page 407: ...Administrator panel Chapter 8 Help topics for the InfoPrint 4100 operator console 393...
Page 408: ...394 Operating the InfoPrint 4100...
Page 461: ......
Page 462: ...Program Number 5765 G79 5765 G74 Printed in USA S550 1298 02...