16
H
OW
TO
EXIT
OUT
OF
A
MENU
Press the
Right
key (Exit). This will take you back to the Patient Menu screen.
H
OW
TO
EXIT
OUT
OF
AN
ITEM
WITHIN
THE
MENU
Press the
Right
key (Exit).
H
OW
TO
C
HANGE
THE
R
AMP
T
IME
During ramp time, the pressure increases from a low pressure to the prescribed
treatment pressure. You can set the ramp time in 5-minute intervals, from 0 minutes
(OFF) up to a maximum ramp time set by your clinician.
The standby screen displays the current ramp time in the right-hand corner. To change
the ramp time, press the
Up
or
Down
key until the desired ramp time appears.
Once a ramp time is selected, begin therapy by pressing the
Start/Stop
key.
When ramping begins the LCD will display the word "RAMPING", with the current
pressure indicated as dashes. Each dash is approximately equivalent to 2 cm H
2
O. For
example, six dashes represents approximately 12 cm H
2
O pressure.
H
OW
TO
CHANGE
THE
A
LTITUDE
SETTING
If you move or travel with your
S8 E
SCAPE
to areas of different altitude, you will need
to adjust the altitude compensation setting. Changes in altitude will affect the pressure
delivered by the
S8 E
SCAPE
.
You can use the Altitude setting (ALT) to specify the altitude range at which you are
using your
S8 E
SCAPE
.
Select the
S8 E
SCAPE
menu by pressing the
Left
key in the
standby (RAMP) screen. Scroll to ALT and select Change (
Left
key).
Press the
Up
or
Down
keys until you see the setting option that you require.
There are four altitude settings to choose from:
•
0–609 m
•
610–1219 m
•
1220–1828 m
•
1829–2591 m.
For example, if you are at an altitude of 947 m, your altitude compensation setting
would be 610–1219 m, as 947 m falls within that range.
Press the
Left
key
(Apply) to select the correct setting.
H
OW
TO
CHANGE
THE
LANGUAGE
SETTING
To display menus and messages in a different language, select the
S8 E
SCAPE
menu by
pressing the
Left
key in the standby (Ramp) screen. Scroll to LANG and select Change
(
Left
key).
Press the
Up
or
Down
keys until you see the language that you require.
O
THER
VIEWABLE
INFORMATION
You can also view the total number of hours of treatment (USED HRS); the number
of sessions that the
S8 E
SCAPE
was used in a usage period (USAGE); and the current
software version installed on your unit (SW). Access to all of these screens is provided
via the menu. See “How to enter the menu screens” on page 15.
338223r1.book Page 16 Friday, June 3, 2005 4:16 PM
Summary of Contents for S8 ESCAPE S8
Page 6: ...1 USER S MANUAL English S8 Escape System E NGLISH ...
Page 7: ...2 ...
Page 42: ...37 BEDIENUNGSANLEITUNG Deutsch S8 Escape System D EUTSCH ...
Page 43: ...38 ...
Page 72: ...67 D EUTSCH TECHNISCHE DATEN Gefährliche Spannung Start Stopp ...
Page 80: ...75 MANUEL UTILISATEUR Français S8 Escape F RANÇAIS ...
Page 81: ...76 ...
Page 110: ...105 F RANÇAIS CARACTERISTIQUES Haute tension Marche Arrêt ...
Page 118: ...113 MANUALE DELL UTENTE Italiano Sistema S8 Escape I TALIANO ...
Page 119: ...114 ...
Page 153: ...148 148 ...
Page 156: ...151 MANUAL DEL USUARIO Español Sistema S8 Escape E SPAÑOL ...
Page 157: ...152 ...
Page 191: ...186 ...
Page 194: ...189 MANUAL DO UTILIZADOR Português Sistema S8 Escape P ORTUGUÊS ...
Page 195: ...190 ...
Page 229: ...224 ...
Page 232: ...227 HANDLEIDING VOOR DE GEBRUIKER Nederlands S8 Escape Systeem N EDERLANDS ...
Page 233: ...228 ...
Page 267: ...262 ...