CHAPTER 8 TIMER RJ
Page 232 of 920
8.4.2
Timer Mode
In this mode, the counter is decremented by the count source selected by bits TCK0 to TCK2 in the TRJMR0
register.
In timer mode, the count value is decremented by 1 each time the count source is input. When the count value
reaches 0000H and the next count source is input, an underflow occurs and an interrupt request is generated.
Figure 8 - 8 shows the Operation Example in Timer Mode.
Figure 8 - 8 Operation Example in Timer Mode
Timer RJ0 counter
Counter reloading occurs
Set to 0 by a
program
Count source
Reload register
TUNDF bit in
TRJCR0 register
02FAH02F9H02F8H02F7H1010H100FH100EH •••••
••••• 0000H1010H100FH100EH100DH100CH100BH
Previous value
(0300H)
New value
(1010H)
Acknowledgement of an interrupt request
IF bit in INTTRJ0 register
An underflow
occurs