CHAPTER 6 CLOCK GENERATOR
Page 127 of 920
Caution
Change the main system clock (f
MAIN
) by the CKC register within the operable voltage range of the
flash operation mode set in the option byte (000C2H) before and after the clock change.
Value of option byte (000C2H)
Flash operation mode
Operating frequency range
Operating voltage range
CMODE0
0
LS (low-speed main) mode
1 MHz to 8 MHz
1.8 V to 3.6 V
1
HS (high-speed main) mode
1 MHz to 16 MHz
2.4 V to 3.6 V
1 MHz to 32 MHz
2.7 V to 3.6 V
Summary of Contents for RL78/G1H