CHAPTER 7 TIMER ARRAY UNIT
Page 147 of 920
The count value can be read by reading timer count register mn (TCRmn).
The count value is set to FFFFH in the following cases.
• When the reset signal is generated
• When the TAUmEN bit of peripheral enable register 0 (PER0) is cleared
• When counting of the slave channel has been completed in the PWM output mode
• When counting of the slave channel has been completed in the delay count mode
The count value is cleared to 0000H in the following cases.
• When the start trigger is input in the capture mode
• When capturing has been completed in the capture mode
Caution
The count value is not captured to timer data register mn (TDRmn) even when the TCRmn register
is read.
The TCRmn register read value differs as follows according to operation mode changes and the operating status.
Note
This indicates the value read from the TCRmn register when channel n has stopped operating as a timer (TEmn = 0) and
has been enabled to operate as a counter (TSmn = 1). The read value is held in the TCRmn register until the count
operation starts.
Remark
m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3)
Table 7 - 2 Timer Count Register mn (TCRmn) Read Value in Various Operation Modes
Operation Mode
Count Mode
Timer count register mn (TCRmn) Read Value
Value if the
operation mode was
changed after
releasing reset
Value if the
Operation was
restarted after count
operation paused
(TTmn = 1)
Value if the
operation mode was
changed after count
operation paused
(TTmn = 1)
Value when waiting
for a start trigger
after one count
Interval timer mode Count down
FFFFH
Value if stop
Undefined
—
Capture mode
Count up
0000H
Value if stop
Undefined
—
Event counter
mode
Count down
FFFFH
Value if stop
Undefined
—
One-count mode
Count down
FFFFH
Value if stop
Undefined
FFFFH
Capture & one-
count mode
Count up
0000H
Value if stop
Undefined
Capture value of
TDRmn register + 1