![PerkinElmer CLARUS 590 GC User Manual Download Page 47](http://html1.mh-extra.com/html/perkinelmer/clarus-590-gc/clarus-590-gc_user-manual_1530196047.webp)
Detectors . 47
Configuration Settings
The following graphic shows the
Configuration Screen
with the settings that appear on the
Active
Method Screen
.
Active Method
Configuration Screen
Manual Pneumatics
The manual pneumatics version of the FID shares several common elements with the PPC version. The
only difference is that the gas flow settings do not appear on the screen. The Auto-Ignite feature is not
available with manual pneumatics.
TCD
The Thermal Conductivity Detector (TCD) is a dual-channel detector which measures the difference in
thermal conductivity between carrier gas flowing through a reference channel and carrier gas plus sample
flowing through an analytical channel.
Four tungsten-rhenium filaments are connected in a bridge circuit, two in each channel. The TCD is set
up with the same amount of carrier gas flowing through both channels. The presence of a sample
component in the carrier gas flowing through the analytical channel changes the resistance of the
filaments in that channel. This unbalances the bridge and produces a signal proportional to the amount of
sample.
The following screens show the
Active Method
screen and the corresponding settings in the
Configuration
screen.
Summary of Contents for CLARUS 590 GC
Page 1: ...CLARUS 590 GC User s Guide GAS CHROMATOGRAPHY ...
Page 9: ...About This Manual 9 Flame Ionization Detector FID 270 TCD 273 Autosampler 277 Index 279 ...
Page 10: ...10 Clarus 590 GC User s Guide ...
Page 11: ...1 Introduction ...
Page 12: ...12 Clarus 590 GC User s Guide ...
Page 21: ...2 Touch Screen Navigation ...
Page 22: ...22 Clarus 590 GC User s Guide ...
Page 48: ...48 Clarus 590 GC User s Guide PPC Active Method Configuration Screen Manual Pneumatics ...
Page 50: ...50 Clarus 590 GC User s Guide PPC Active Method Configuration Screen Manual Pneumatics ...
Page 59: ...3 Using the Active Method ...
Page 60: ...60 Clarus 590 GC User s Guide ...
Page 109: ...4 Setting Up the Detectors ...
Page 110: ...110 Clarus 590 GC User s Guide ...
Page 197: ...5 Using the Method Editor ...
Page 198: ...198 Clarus 590 GC User s Guide ...
Page 207: ...6 Using the Tools Menu ...
Page 208: ...208 Clarus 590 GC User s Guide ...
Page 224: ...224 Clarus 590 GC User s Guide ECD PID NPD FPD ...
Page 225: ...Detectors 225 Output Configured ...
Page 262: ...262 Clarus 590 GC User s Guide ...
Page 263: ...7 Setting up a Typical Analysis ...
Page 264: ...264 Clarus 590 GC User s Guide ...
Page 279: ...Index ...
Page 280: ...280 Clarus 590 GC User s Guide ...