18 . Clarus 590 GC User’s Guide
Term
Description
Equilibration
The delay time after the method set points have been
reached before the system becomes READY.
Flameout
PPC version only. Detects if the flame is on to prevent
injection into a nonfunctioning system and subsequent
loss of sample.
Isothermal
method
A method in which the oven temperature remains
constant throughout a GC run.
Method
A collection of parameters that control the GC.
Negative-time
event
A timed event that you set to occur before the
instrument becomes READY.
Parameter
An independent variable used to specify a condition to
be met.
PPC
Programmable Pneumatic Control
Pre-run
The time after equilibration during which negative-time
events are executed.
PreVent
PPC version only. Sample management system.
Range
Range means amplification of the detector output
signal.
Ready
Indicates that all method parameters have reached their
set points and that you can start your analysis.
Run
The time from sample injection to the end of the oven
temperature program.
Sleep mode
The GC can be set to a predefined method for gas
savings.
Temperature
program
PPC version only. A program that specifies the rate of
oven temperature increase from one plateau to the
next, and the time the oven temperature is held
constant at a plateau.
Timed Events Events that take place before or during a GC run as
specified in a timed events table.
Zone
A heated area in the GC oven, injector, or detector.
Summary of Contents for CLARUS 590 GC
Page 1: ...CLARUS 590 GC User s Guide GAS CHROMATOGRAPHY ...
Page 9: ...About This Manual 9 Flame Ionization Detector FID 270 TCD 273 Autosampler 277 Index 279 ...
Page 10: ...10 Clarus 590 GC User s Guide ...
Page 11: ...1 Introduction ...
Page 12: ...12 Clarus 590 GC User s Guide ...
Page 21: ...2 Touch Screen Navigation ...
Page 22: ...22 Clarus 590 GC User s Guide ...
Page 48: ...48 Clarus 590 GC User s Guide PPC Active Method Configuration Screen Manual Pneumatics ...
Page 50: ...50 Clarus 590 GC User s Guide PPC Active Method Configuration Screen Manual Pneumatics ...
Page 59: ...3 Using the Active Method ...
Page 60: ...60 Clarus 590 GC User s Guide ...
Page 109: ...4 Setting Up the Detectors ...
Page 110: ...110 Clarus 590 GC User s Guide ...
Page 197: ...5 Using the Method Editor ...
Page 198: ...198 Clarus 590 GC User s Guide ...
Page 207: ...6 Using the Tools Menu ...
Page 208: ...208 Clarus 590 GC User s Guide ...
Page 224: ...224 Clarus 590 GC User s Guide ECD PID NPD FPD ...
Page 225: ...Detectors 225 Output Configured ...
Page 262: ...262 Clarus 590 GC User s Guide ...
Page 263: ...7 Setting up a Typical Analysis ...
Page 264: ...264 Clarus 590 GC User s Guide ...
Page 279: ...Index ...
Page 280: ...280 Clarus 590 GC User s Guide ...