62
Signal Tower LA6-POE Operation Manual
5.8. HTTP Command Control
This product can be controlled by transmitting a HTTP command from the HTTP client.
[Specification of HTTP command control]
Protocol
HTTP
Method
GET
Syntax
http://<IP address>/api/control?<parameter name>=<value>[&<parameter name>=<value>]
Response
Success.
The parameter name is correct.
Error.
The parameter name is incorrect.
Parameter
Values
Description
alert=< integer value >
6 digits
Each LED unit tier and buzzer can be controlled with the pattern.
Specify the pattern in order of [Tier 1, Tier 2, Tire 3, Tier 4, Tier 5, Buzzer].
[Tier 1 -5 ] 0 : Off, 1 : On, 2 : Flashing, 9 : No Change
[Buzzer] 0 : Stop, 1 : Pattern 1, 2 : Pattern 2, 3 : Buzzer sound at a
simultaneous buzzer input, 9 : No Change
smart=< integer value > 1 - 31
The Smart Mode can be executed with the number.
pulse=< integer value > 1
The pattern can be changed when the pulse torigger mode operation.
mute=< integer value >
0, 1
The On/Off of the buzzer is controllable when executing in Smart Mode.
stop=< integer value >
0, 1
The pattern stop/restart can be controlled when the time torigger mode
operation.
color=< integer value >
5 digits
The color of each LED unit tier can be controlled.
0 : Off, 1 : Red, 2 : Amber, 3 : Lemon, 4 : Green, 5 : Sky Blue, 6 : Blue, 7 : Purple,
8 : Pink, 9 : White
buzzer=< integer value > 0 - 11
Buzzer pattern can be controlled.
0 : Stop, 1 - 11 : Buzzer patterns 1 - 11.
flash=< integer value >
1
The LED unit will flash.
clear=< integer value >
1
Turn off the LED unit and stop the buzzer.
MEMO
• Please specify "color" and "buzzer" with one command.
• The parameters that can be specified at the one command are as follows.
»
smart&pulse
»
color&buzzer
»
color&buzzer&flash