60
Signal Tower LA6-POE Operation Manual
5.7. Contact Input Detection
Use the contact inputs 1-4 to perform the operation set up by operating the contacts. The operation can be selected from
"No operation", "Clear", "mute", "STOP", and "Trigger". (Refer to “4.8 Contact Input Detection” on page 27)
Select Operation
Operation Contents
No Operation
• It doesn't operate.
Clear
• By turning on the contact set up to clear, the "Clear" operation will be
executed. (Refer to "5.6 "Clear" Function" on page 59)
Mute
• By turning on the contact set up for mute, the Mute input is turned on.
• While the mute input is set to ON, the buzzer will not sound.
• When the contact is turned off, the Mute input will also turn off.
STOP
• By turning on the contact set up for STOP, the STOP input will turn ON.
• While the STOP input is ON, the operation for the STOP input is executed.
• When the contact is turned OFF, the STOP input will also turn off.
Pulse
Trigger
• By turning on the contact set up for the pulse trigger input, the operation for
the pulse trigger is turned on.
• Whenever the contact is turned on, the pattern changes.
MEMO
• The contact input detection function can be performed only while using the command
control method.
• The Mute input is effective only while the Smart mode is running.
• The STOP input is effective only when the time trigger type in Smart mode is running.
• The trigger input is effective only during pulse trigger mode when Smart mode is running.