36
Signal Tower LA6-POE Operation Manual
5.1.4. Managing Command Control
Command Description
Each LED unit tier and buzzer (1-3) can be controlled with the pattern specified in the data area.
It operates with the color and buzzer set up in the Signal Tower mode.
Transmission Data Format
Product Category
AB
Identifier
S
Open
Data Size
Data Area 6 bytes
41H
42H
53H
00H
00H
06H
See Below
Product Category
The product is classified in “AB.”
Identifiers
“S” is used.
Data Area
Data Area 6 bytes
LED Unit
Buzzer
1
2
3
4
5
6
Tier 1
Pattern
Tier 2
Pattern
Tier 3
Pattern
Tier 4
Pattern
Tier 5
Pattern
Patterns
1,2,3
LED Unit
Buzzer
00H: Off
00H: Stop
01H: On
01H: Pattern 1
02H: Flashing
02H: Pattern 2
09H: No Change
03H: Buzzer sound at a simultaneous buzzer input
09H: No Change
Command Transmission Example
1st Tier: lighting, 2nd tier/3rd tier: flashing, 4th tier: Off, 5th tier: no change, buzzer: pattern 1
Product Category
AB
Identifier
S
Open
Data Size
Data Area
41H
42H
53H
00H
00H
06H
01H
02H
02H
00H
09H
01H
Reply Data
Normal Response (1 byte)
Abnormal Response (1 byte)
ACK
NAK
06H
15H