31
Signal Tower LA6-POE Operation Manual
4.10. Information Transmission Setup
Set the Destination Address of the signal tower information, signal tower input judgment,smart-mode information to send.
1 Attach the lead wires.
2 Attach the LAN cable.
3 Display the "Main Unit Setup" screen.
"4.5. Main Unit Setup" on
page 24
4 Set to the "Signal Wire Control".
5 Display the "Information Transmision Setup" screen.
On this page
6 Enter the IP address and port number to transmit Signal Tower Information
7 Select Smart-mode information to send.
8 Select Signal Tower input judgment.
Item
Contents
Default
Value
Input
Parameter
Destination
Address
Enter the destination IP address of Signal Tower Information.
IP Address
Format
Port Number
Enter the destinatio Port Number of Signal Tower Information.
10000
1024-65535
Send Smart-mode
information
Select the transmitted infromation when operating in Smart Mode.
<Pattern transition information >
Every time a pattern transition, send the Signal Tower information.
<Takt time Overdue>
When the takt time overdue,send the Signal Tower information.
Takt time
Overdue
-
Signal Tower input
judgment
Select the process used to determine the Signal Tower input status.
<Flashing Judgment ( Short : 0.7 Sec) >
Flashing is determined when there are two status changes within 0.7 seconds.
<Flashing Judgment ( Medium : 1.5 Sec) >
Flashing is determined when there are two status changes within 1.5 seconds.
<Flashing Judgment ( Long : 2.5 Sec) >
Flashing is determined when there are two status changes within 2.5 seconds.
Medium
-