Signal Tower LA6-POE Operation Manual
3. Installation
!
CAUTION
The clamping surface should be sufficient enough to tolerate the weight and surface of the product. Do not use the
product in a place where vibrations exceeds the specifications. Failure to comply may result in the prevention of the
product detaching and falling, causing injury to a passer-by, etc.
Install the signal tower in an upright position.
In cases where the installation placement is unavoidably irregular, and waterproof performance is required, use a
sealant to the crevice between the product and the installation surface. ( TN )
If an IP54 rating is required, when clamping each bracket, place sealant to the distribution hole area and the
screw thread or nut.
( TN )
Do not run LAN cable from outside. There is a risk of exposure to lightning strikes or other adverse weather
conditions.
The LAN Unit and Stand Cover cannot be separated.
( SN )
Before placing the rubber sheet onto the bottom plate, be sure to removedust, water, oil, etc., on the bottom plate and the
installation location. ( SN )
The LAN cable and wiring is not included.
3.1. How to Install
3.1.1. Direct-mount Type
❶
Make holes for the mount and wire
distribution hole for the product.
❷
Firmly hold the LAN Unit, and the turn
to the left to remove it.
❸
Secure the LAN bracket with the
accessorized nuts.
Recommended Torque
0.75N/m (Standard)
❹
It allows the LAN cable wiring to pass
through the distribution hole.
❺
The lock on the terminal block
connector can be unlocked and
removed for wiring.
(Refer to “3.3.3. Terminal block
connector detachment method”)
(Refer to “3.4. Wiring”)
❻
T
he LAN unit is connected to the
terminal block connector and LAN
cable.
❼
T
he LAN unit is attached.
❽
S
ealing around the mounting holes
and the distribution hole is done if
necessary.
※
The figure shows the most common installation circumstances,
but cannot show for every possible circumstance.
Terminal Block Connector
LAN Cable
LAN Unit
LAN
Bracket
※Mounting Board
Thickness 4mm or less.
2
5
7
6
4
8
1
3
Mounting Dimensional Drawing
■
Mounting Hole
(φ5×3 places)
φ
40
120°
Nameplate
Location
Product Front
(Buzzer Diaphram)
Product
Outside
Dimension
Distribution Hole
(φ26)
120°
(Unit: mm)