5. Operating Procedure
5.1. PNS Command
By sending PNS commands from a PC etc., you can control and obtain the status of this product. The protocol can
be selected from “TCP” or “UDP.”
Communication port numbers are “10000-65535.”
MEMO
• The PNS command setup can be executed with the command reception setting. ( Refer to "4.6.
RSH Command Configuration.")
• The number of simultaneous connections with a PNS Command and PHN Command is 8
connections.
Identifier List
Identifiers Command Name
Outline
T(54H)
Smart Mode Control
Execute the Smart Mode.
M(4DH)
Mute
Switches the buzzer ON/OFF when operating in Smart Mode.
P(50H)
STOP/Pulse Input
An input can be entered in the Smart Mode operation.
Time Trigger Type Operation: STOP Input ON/OFF
Pulse Trigger Type Operation: Pulse Trigger Input
S(53H)
Motion Control
Control 1-5 tiers of the LED unit with a set color.
D(44H)
Detailed Motion Control
Control 1-5 tiers of the LED unit by specifying the color.
C(43H)
Clear
Turn off the LED unit.
Stop the buzzer.
B(42H)
Reboot
This product is rebooting.
G(47H)
Status Acquisition
The status of this machine is acquired.
E(45H)
Detailed Status Acquisition
The detailed status of this machine can be acquired.
Excecutable command in each control method ( is executable)
Identifiers
Command Name
Command Control Method Signal Wire Control Method
T(54H)
Smart Mode Control
×
M(4DH)
Mute
×
P(50H)
STOP/Pulse Input
×
S(53H)
Motion Control
×
D(44H)
Detailed Motion Control
×
C(43H)
Clear
×
B(42H)
Reboot
G(47H)
Status Acquisition
E(45H)
Detailed Status Acquisition