Signal Tower LA6-POE Operation Manual
5.3.3. Register Address
The register address list supported by this product.
Register Address Control Allocation
Data
Condition
1 (01H)
1st LED Unit Tier
MSN
00H: doesn't control, 01H: controls
LSN
00H: OFF, 01H : ON, 02H: flashing, 09H: No Change
2 (02H)
2nd LED Unit Tier
MSN
00H: doesn't control, 01H: controls
LSN
00H: OFF, 01H : ON, 02H: flashing, 09H: No Change
3 (03H)
3rd LED Unit Tier
MSN
00H: doesn't control, 01H: controls
LSN
00H: OFF, 01H : ON, 02H: flashing, 09H: No Change
4 (04H)
4th LED Unit Tier
MSN
00H: doesn't control, 01H: controls
LSN
00H: OFF, 01H : ON, 02H: flashing, 09H: No Change
5 (05H)
5th LED Unit Tier
MSN
00H: doesn't control, 01H: controls
LSN
00H: OFF, 01H : ON, 02H: flashing, 09H: No Change
6 (06H)
Buzzer
MSN
00H: doesn't control, 01H: controls
LSN
00H: STOP, 01H-0BH: buzzer patterns 1-11
7 (07H)
Smart Mode
MSN
00H: doesn't control, 01H: controls
LSN
01H-1FH: Group Numbers 1-31
8 (08H)
Clear
MSN
00H (Fixed settings)
LSN
Clear (00H: No Change, 01H: Execute Clear)
9 (09H)
Mute
MSN
00H (Fixed settings)
LSN
Mute (00H:Mute cancel, 01H: Mute execution)
10 (0AH)
STOP
MSN
00H (Fixed settings)
LSN
STOP (00H:STOP cancel, 01H:STOP execution)
11 (0BH)
Pulse Trigger Input
MSN
00H (Fixed settings)
LSN
Pulse Trigger (00H: No Change, 01H: pattern change)
MEMO
• When executing smart mode, set register addresses 1-6 to "doesn't control" (00H).
• Execution priority is in the order of "Clear", "LED Unit", "Smart mode".
• The buzzer pattern that can be specified with "Write Single Register" or "Write Multiple Regis-
ters" is 1 to 3.
• PNS Commands Up to 11 buzzer patterns can acquired during detailed motion control.
• When executing single display type, up to 31 (01H-1FH) group numbers in smart mode can be designated.
• To execute the time trigger type or pulse trigger type, up to 15 (01H - 0FH) smart mode groups
can be specified when setting up.
5.3.4. Example
Coil/Register Numbers Input Address
Control Allocation
Example Data Integer
10001
1 (01H)
Contact Input 1
Input 1 on: 1
10002
2 (02H)
Contact Input 2
Input 2 on: 1
10003
3 (03H)
Contact Input 3
Input 3 on: 1
10004
4 (04H)
Contact Input 4
Input 4 on: 1
10005
5 (05H)
Contact Input 5
Input 5 on: 1
10006
6 (06H)
Contact Input 6
Input 6 on: 1
10007
7 (07H)
Contact Input 7
Input 7 on: 1
10008
8 (08H)
Contact Input 8
Input 8 on: 1