Appendix Function Parameter List
14
3
■
3-wire run/stop command
Please assign “3-wire stop command” to any input terminal of SW1 to SW5.
The following connection example indicates the situation that “3-wire stop
command” is assigned to input terminal SW1.
Setting
value
Command
status
Panel reset
function
Operation method and control circuit terminal
connection diagram
2
External
control
×
4
External
control
○
Common terminal
(Ternimal No. 1 or No. 8)
ON: Start
ON: Reverse run/OFF:
Forward run
ON: Stop (*1)
3
External
control
×
5
External
control
○
Common terminal
(Ternimal No. 1 or No. 8)
ON: Forward run
ON: Reverse run
ON: Stop (*1)
(*1) If any terminal of SW1 to SW5 (control circuit terminal No. 4 to No. 8) is
used as “3-wire stop command”, please set “P036 to P040: SW1 to SW5
Function Select” to “10” (3-wire stop command). In addition, please note
that even if “P041: Input Logic Setting” is set to “a contact input”, “b
contact input” will still apply.
■
Panel reset function
When a fault trip occurs, reset cannot be made with stop signal input from
external devices. Therefore, use STOP SW on the panel to reset the fault trip.
But if the reset lock function is used, it will take precedence. In addition, reset
fuction is also valid.
・
If forward run and reverse run signal are turned ON simultaneously, the
operation status will not be changed. If the inverter is stopped and both
signals are turned ON simultaneously, the operation will not start.
Related parameters: P036 to P040
Summary of Contents for VF200
Page 1: ...VF200 WME VF200 A 2013 01 panasonic net id pidsx global ...
Page 2: ......
Page 7: ......
Page 8: ...1 Safety Precautions ...
Page 14: ...Safety Precautions 7 7 Warning Label on Inverter VF200 ...
Page 15: ...Safety Precautions 8 ...
Page 16: ...9 Points for Handling Special Precautions 10 ...
Page 19: ...Points for Handling ...
Page 20: ...13 1 Parts Identification 1 1 Part Names and Functions 14 1 2 Details on Part Number 16 ...
Page 29: ...2 Installation 22 VF200 ...
Page 49: ...42 ...
Page 56: ...4 Operation Method Basic Operation ...
Page 75: ...4 Operation Method Basic Operation ...
Page 101: ...6 Function Parameters 94 ...
Page 102: ...95 7 Custom Mode 7 1 Allocating Parameter No 96 7 2 Setting and Changing Parameters 98 ...
Page 107: ...7 Custom Mode 100 ...
Page 119: ...8 Setting Mode and Copy Function of Built in Memory 112 ...
Page 126: ...9 Troubleshooting 119 9 3 3 Breaker Trip 9 3 4 Motor Overheating 9 3 5 Communication Failed ...
Page 127: ...9 Troubleshooting 120 ...
Page 145: ...11 Specifications 138 ...
Page 146: ...139 Appendix Function Parameter List ...