Appendix Function Parameter List
141
P002
The 1
st
Deceleration Time
The time to decelerate from the maximum output frequency to 0.5 Hz can be
set.
Data setting range (s) 0.04
·
0.1 to 3600
Increment (s)
0.1 (0.1 to 999.9),
1 (1000 to 3600)
・
The display code for "0.04 s” is “0000”.
・
The maximum output frequency is set with parameter P005 and P008.
・
Please note that if the deceleration time setting is too small, overcurrent may
occur depending on the load.
Related parameters: P005, P008