2-14
A to D-frame, 100 V / 200 V type
:LULQJVKRXOGEHSHUIRUPHGE\DVSHFLDOLVWRUDQDXWKRUL]HGSHUVRQQHO
'RQRWWXUQRQWKHSRZHUXQWLOWKHZLULQJLVFRPSOHWHG
1HYHUWRXFKWKHSRZHUFRQQHFWRU;$DQG;%WRZKLFKKLJKYROWDJHLVDSSOLHG
There is a risk of electric shock.
Tips on Wiring
1) Wire connector (XA and XB).
2) Connect the wired connector to the driver.
Fully insert the connector to the bottom until it clicks.
Motor
Varistor
DC
24V
MCCB
Power
supply
NF
MC
U
V
W
E
L
Fuse (125 V 10 A)
&KHFNWKHQDPHSODWHRIWKHGULYHUIRUSRZHU
VSHFLILFDWLRQV
3URYLGHDUHVLGXDOFXUUHQWGHYLFH7KHUHVLGXDO
FXUUHQWGHYLFHWREHWKHRQHGHVLJQHGIRU,QYHUWHU
DQGLVHTXLSSHGZLWKFRXQWHUPHDVXUHVIRUKDUPRQLFV
3URYLGHDFLUFXLWEUHDNHU
0DNHVXUHWRSURYLGHDQRLVHILOWHU
3URYLGHFRLOVXUJHVXSSUHVVLRQXQLWVWRWKHFRLORIWKH
0DJQHWLF&RQWDFWRUUHFRPPHQGHGE\PDQXIDFWXUHU
Never start/stop the motor with this Magnetic
Contactor.
3URYLGHDQ$&5HDFWRU
Connect L1 and L1C, and L3 and L2C at single
phase use (100V and 200V), and don't use L2.
0DWFKWKHFRORUVRIWKHPRWRUOHDGZLUHVWRWKRVHRIWKH
FRUUHVSRQGLQJPRWRURXWSXWWHUPLQDOV89:
'RQWGLVFRQQHFWWKHVKRUWLQJFDEOHEHWZHHQ%DQG%
&DQG'IUDPHW\SH6KRUWLQJFDEOHLVQRWUHTXLUHGIRU
$DQG%IUDPH'LVFRQQHFWWKLVRQO\ZKHQWKHH[WHUQDO
UHJHQHUDWLYHUHJLVWHULVXVHG
Avoid shorting and grounding. Don't connect the
main power.
Earth-ground this.
7RSUHYHQWHOHFWULFVKRFNEHVXUHWRFRQQHFWWKHJURXQG
WHUPLQDORIWKHGULYHUDQGWKHJURXQGWHUPLQDO
JURXQGSODWHRIWKHFRQWUROSDQHO
7KHJURXQGWHUPLQDOPXVWQRWEHVKDUHGZLWKRWKHU
HTXLSPHQW
7ZRJURXQGWHUPLQDOVDUHSURYLGHG
Don't connect the earth cable to other inserting slot,
nor make them touch.
&RPSRVHDGXSOH[%UDNH&RQWURO&LUFXLWVRWKDWWKH
EUDNHFDQDOVREHDFWLYDWHGE\DQH[WHUQDOLPPHGLDWH
VWRSVLJQDO
7KHKROGLQJEUDNHKDVQRSRODULWLHV
)RUWKHKROGLQJEUDNHSRZHUVXSSO\FDSDFLW\DQGKRZWR
XVHWKHEUDNHUHIHUWR´6SHFLILFDWLRQVRI%ROGLQJ
%UDNHµRQ3
3URYLGHDYDULVWRU
&RQQHFWD$IXVHLQVHULHVZLWKWKHYDULVWRU
*URXQGUHVLVWDQFHїPD[
)RUDSSOLFDEOHZLUHUHIHUWR3
L1C
/
L2
L1
L2C
B1
%
B2
U
V
W
XA
XB
2
3
4
5
1
2
3
4
5
6
1
DC power supply
IRUEUDNH
5HG
%ODFN
*UHHQRU
*UHHQ\HOORZ
:KLWH
5&'
([WHUQDOUHJHQHUDWLYH
resistor
7KHVHFRORUV
DUHXVHGIRU
RSWLRQDOFDEOH
Note
Related page
The wiring indicated with the broken line shall be provided only when required.
3´6SHFLÀFDWLRQVRI0RWRUFRQQHFWRUµ3´:LULQJPHWKRGWRFRQQHFWRUµ
3´&RQQHFWRUNLWIRU;$µ3´&RQQHFWRUNLWIRU;%µ
2
Preparation
2.
6\VWHP&RQÀJXUDWLRQDQG:LULQJ
Wiring of the Main Circuit (A to D-frame, 100/200 V type)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for MINAS A5 Series
Page 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...