4-35
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
'HIDXOW>@
Pr4.10
*
SO1 output selection
Range
Unit
Default
Related
control mode
0 to 00FFFFFFh
—
00030303h
P S T F
Caution
$VVLJQIXQFWLRQVWR62RXWSXWV
7KHVHSDUDPHWHUVDUHSUHVHQWHGLQKH[DGHFLPDOV
*
1
+H[DGHFLPDOSUHVHQWDWLRQLVIROORZHGE\DVSHFLÀFFRQWUROPRGHGHVLJQDWLRQ
0 0 – – – –
* *
K SRVLWLRQIXOOFORVHGFRQWURO
0 0 – –
* *
² ² K YHORFLW\FRQWURO
0 0
* *
² ² ² ² K WRUTXHFRQWURO
Replace
* *
ZLWKWKHIXQFWLRQQXPEHU
)RUWKHIXQFWLRQQXPEHUVHHWKHWDEOHEHORZ/RJLFDOVHWXSLVDOVRDIXQFWLRQQXPEHU
Setup
value
Title
Symbol
Note
)RURXWSXWSLQDVVLJQPHQWZLWK
GHIDXOWVHWWLQJDOVRUHIHUWR3
2XWSXWVLJQDOVFRPPRQ
and their functions.
Related page
P.3-52
([DPSOHRIFKDQJH!
To change the default setting
´([WHUQDOEUDNHUHOHDVHVLJQDOµ
LQDOOPRGHVWR´$ODUPRXWSXW
µVHWWKHLQSXWWRK
)RUHDVLHUVHWWLQJXVHWKH
VHWXSVXSSRUWVRIWZDUH
3$1$7(50
00h
,QYDOLG
ï
02h
6HUYR5HDG\RXWSXW
S-RDY
03h
([WHUQDOEUDNHUHOHDVH
signal
BRK-OFF
04h
Positioning complete output
,13
05h
$WVSHHGRXWSXW
$7633('
06h
Torque in-limit signal output
TLC
07h
Zero-speed detection output signal
ZSP
08h
Speed coincidence output
9&2,1
09h
$ODUPRXWSXW
:$51
$K
$ODUPRXWSXW
:$51
0Bh
3RVLWLRQDOFRPPDQG212))RXWSXW
P-CMD
0Ch
Positioning complete 2
,13
0Dh
Speed in-limit output
V-LIMIT
0Eh
$ODUPDWWULEXWHRXWSXW
$/0$7%
0Fh
6SHHGFRPPDQG212))RXWSXW
V-CMD
Same function can be assigned to 2 or more output signals.
&RQWURORXWSXWSLQVHWWRLQYDOLGDOZD\VKDVWKHRXWSXWWUDQVLVWRUWXUQHG2))
'RQRWFKDQJHWKHVHWXSYDOXHVKRZQLQWKHWDEOH
*
1RWHWKDWWKHVHWXSYDOXHVDUHGLVSOD\HGLQGHFLPDORQWKHIURQWSDQHO
Pr4.11
*
SO2 output selection
Range
Unit
Default
Related
control mode
0 to 00FFFFFFh
—
00020202h
P S T F
Pr4.12
*
SO3 output selection
Range
Unit
Default
Related
control mode
0 to 00FFFFFFh
—
00010101h
P S T F
Pr4.13
*
SO4 output selection
Range
Unit
Default
Related
control mode
0 to 00FFFFFFh
—
00050504h
P S T F
Pr4.14
*
SO5 output selection
Range
Unit
Default
Related
control mode
0 to 00FFFFFFh
—
00070707h
P S T F
Pr4.15
*
SO6 output selection
Range
Unit
Default
Related
control mode
0 to 00FFFFFFh
—
00060606h
P S T F
$VVLJQIXQFWLRQVWR62WR62RXWSXWV
7KHVHSDUDPHWHUVDUHSUHVHQWHGLQKH[DGHFLPDOV
Setup procedure is the same as described for Pr4.10.
1. Details of parameter
[Class 4] I/F monitor setting
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for MINAS A5 Series
Page 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...