Protective
function
Error code No.
Causes
Measures
Main Sub
6-13
1. When in Trouble
Protective function (Detail of error code)
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
*
A-phase
wiring error
protection
55
0
A-phase wiring in the external scale is
defective, e.g. discontinued.
Check the A-phase wiring connection.
*
B-phase
wiring error
protection
1
B-phase wiring in the external scale is
defective, e.g. discontinued.
Check the B-phase wiring connection.
*
Z-phase
wiring error
protection
2
Z-phase wiring in the external scale is
defective, e.g. discontinued.
Check the Z-phase wiring connection.
Forced
alarm input
protection
87
0
Forced alarm input (E-STOP) is applied.
Check the wiring of forced alarm input
(E-STOP).
*
Motor
automatic
recognition
error
protection
95 0 to 4
The motor and the driver has not been
matched.
Replace the motor which matches to the
driver.
*
Other error
99
0
Excessive noise or the like is detected as
an abnormal signal.
This type of error will occur if the alarm
clear is attempted while the safety input
1/safety input 2 is not in normal state
(input photocoupler is ON).
7XUQRIIWKHSRZHURQFHWKHQUHHQWHU
,IHUURUUHSHDWVWKLVPLJKWEHDIDLOXUH
Stop using the products, and replace the
motor and the driver. Return the products to
the dealer or manufacturer.
$GMXVWWKHFRQGLWLRQRIWKHVDIHW\LQSXW
safety input 2 and then start the alarm clear.
Other
No.
Control circuit has malfunctioned due to
excess noise or other causes.
Some error has occurred inside of the
driver while triggering self-diagnosis
function of the driver.
7XUQRIIWKHSRZHURQFHWKHQUHHQWHU
,IHUURUUHSHDWVWKLVPLJKWEHDIDLOXUH
Stop using the products, and replace the
motor and the driver. Return the products to
the dealer or manufacturer.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for MINAS A5 Series
Page 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...