3-26
3. Wiring Diagram to the connector, X4
Connecting Example to Host Controller
Connection between MINAS A5 and CJ1W-NC113 (Omron Corp.)
Note
5HODWHGSDJH
UHSUHVHQWVWZLVWHGSDLUZLUH
3´,QSXWVDQGRXWSXWVRQFRQQHFWRU;µ
A5-series
CJ1W-NC113
(Omron Corp.)
from
PLC I/O
output
to
PLC I/O
input
GND
+ 24V
DC24V
Power supply
Command pulse
input 2
Counter clear input
Servo-ON input
Servo-Ready output
Servo-Alarm output
Positioning complete
output
Alarm clear input
Inhibit negative direction
travel input
Inhibit positive direction
travel input
Z-phase output
Command sign
input 2
Gain switching input
Driver
PLC
CCW limit sensor
Origin proximity sensor
CW limit sensor
CW pulse command
output
CCW pulse command
output
Origin line driver
input
Power supply
for output
Deviation counter
reset output
Emergency stop
input
Origin proximity
input
CCW limit excess
input
CW limit excess
input
* Process of shield wire varies with equipment.
50
3
4
5
6
23
24
13,25
7
30
29
27
31
9
8
35
34
37
36
39
38
41
FG
PULS1
PULS2
SIGN1
SIGN2
OZ+
OZ−
GND
COM+
CL
SRV-ON
GAIN
A-CLR
POT
NOT
S-RDY+
S-RDY−
ALM+
ALM−
INP+
INP−
COM−
220Ω
220Ω
4.7Ω
4.7Ω
4.7Ω
4.7Ω
4.7Ω
4.7Ω
A6
A8
A16
A14
A1
A2
A10
A24
A20
A21
A23
A22
4.7kΩ
4.7kΩ
4.7kΩ
4.7kΩ
+V
GND
150Ω
1.6kΩ
1.6kΩ
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for MINAS A5 Series
Page 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...