2-97
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
Note
Caution
History
...The error will be stored in the error history.
Can be cleared
...To cancel the error, use the alarm clear input (A-CLR).
If the alarm clear input is not effective, turn off power, remove the cause of the error
and then turn on power again.
Immediate stop
...Instantaneous controlled stop upon occurrence of an error.
(Setting of “Pr.5.10 Sequence at alarm” is also required.)
1) Certain alarms are not included in the history. For detailed information on alarms e.g.
alarm numbers, refer to P.6-2.
2) When one of the errors which are listed in error history occurs, this error and history o
shows the same error No.
15. How to Use the Front Panel
Monitor Mode (EXECUTION display)
Error code
Protective function
Attribute
Main
Sub
History
Can be
cleared
Immediate
stop
34
0
Software limit protection
36
0 to 2 EEPROM parameter error protection
37
0 to 2 EEPROM check code error protection
38
0
Over-travel inhibit input protection
39
0
Analog input1 excess protection
1
Analog input2 excess protection
2
Analog input3 excess protection
40
0
Absolute system down error protection
41
0
Absolute counter over error protection
42
0
Absolute over-speed error protection
43
0
Initialization failure
44
0
Absolute single turn counter error protection
45
0
Absolute multi-turn counter error protection
47
0
Absolute status error protection
48
0
Encoder Z-phase error protection
49
0
Encoder CS signal error protection
50
0
External scale connection error protection
1
External scale communication error protection
51
0
External scale status 0 error protection
1
External scale status 1 error protection
2
External scale status 2 error protection
3
External scale status 3 error protection
4
External scale status 4 error protection
5
External scale status 5 error protection
55
0
A-phase connection error protection
1
B-phase connection error protection
2
Z-phase connection error protection
87
0
Compulsory alarm input protection
95
0 to 4 Motor automatic recognition error protection
Other number Other error
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for MINAS A5 Series
Page 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...