1-32
Install the motor properly to avoid a breakdown or an accident.
Installation Place
Since the conditions of location affect a lot to the motor life, select a place which
meets the conditions below.
1) Indoors, where the products are not subjected to rain or direct sun beam. The products
are not waterproof.
2) Where the products are not subjected to corrosive atmospheres such as hydrogen sul-
ÀGHVXOIXURXVDFLGFKORULQHDPPRQLDVXOIXUFKORULFJDVVXOIXULFJDVDFLGDONDOLQH
DQGVDOWDQGVRRQDQGDUHIUHHIURPVSODVKRILQÁDPPDEOHJDV
3) Where the motor is free from grinding oil, oil mist, iron powder or chips.
4) Well-ventilated and humid and dust-free place, far apart from the heat source such as
a furnace.
5) Easy-to-access place for inspection and cleaning
6) Vibration-free place.
7) Avoid enclosed place. Motor may gets hot in those enclosure and shorten the motor life.
Environmental Conditions
Item
Conditions
Ambient temperature
*
1
Ý&WRÝ&IUHHIURPIUHH]LQJ
Ambient humidity
20% to 85% RH (free from condensation)
Storage temperature
*
2
²Ý&WRÝ&
(Max. temperature guarantee: 80
Ý
C for 72 hours free from condensation
*
5
)
Storage humidity
20% to 85% RH (free from condensation
*
5
)
Vibration Motor only
Lower than 49m/s
2
(5G) at running, 24.5m/s
2
(2.5G) at stall
Impact
Motor only
Lower than 98m/s
2
(10G)
Enclosure
rating
Motor only
(Connector type)
IP67 (except rotating portion of output shaft and connecting pin
part of the motor connector and the encoder connector)
*
3
*
4
Altitude
Lower than 1000m
*
1 Ambient temperature to be measured at 5cm away from the motor.
*
2 Permissible temperature for short duration such as transportation.
*
3
7KHVHPRWRUVFRQIRUPWRWKHWHVWFRQGLWLRQVVSHFLÀHGLQ(1VWDQGDUGV(1(1'R
QRWXVHWKHVHPRWRUVLQDSSOLFDWLRQZKHUHZDWHUSURRISHUIRUPDQFHLVUHTXLUHGVXFKDVFRQWLQXRXV
wash-down operation.
*
4 This condition is applied when the connector mounting screw in case of motor 750W or less are
WLJKWHQHG WR WKH UHFRPPHQGHG WLJKWHQLQJ WRUTXH 5HIHU WR 3 %H VXUH WR XVH PRXQWLQJ
screw supplied with the connector. Correctly install and secure the gasket supplied with the cable
connector.
*
5 Air containing water vapor will become saturated with water vapor as the temperature falls, causing dew.
How to Install
You can mount the motor either horizontally or vertically as long as you observe the followings.
1) Horizontal mounting
0RXQWWKHPRWRUZLWKFDEOHRXWOHWIDFLQJGRZQZDUGIRUZDWHURLOFRXQWHUPHDVXUH
2)Vertical mounting
8VH WKH PRWRU ZLWK RLO VHDO PDNHWRRUGHU LQ FDVH RI PRWRU : RU OHVV ZKHQ
mounting the motor with gear reducer to prevent the reducer oil/grease from entering
to the motor.
1
Before Using
the Products
5. Installation
Motor
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for MINAS A5 Series
Page 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...