7-66
7
5. Motor Characteristics (
S-T
Characteristics
)
Supplement
MFME series
(1.5kW to 4.5kW)
50
100
10
0
20
30
40
0
1000
2000
3000
10
20
Peak running range
Continuous running range
(
21.5
)
(
7.16
)
(
4.8
)
(
14
)
50
100
10
0
20
30
40
0
1000
2000
3000
15
30
Peak running range
Continuous running range
(
30.4
)
(
11.9
)
(
5
)
50
100
10
0
20
30
40
0
1000
2000
3000
25
50
Peak running range
Continuous running range
(
54.9
)
(
21.5
)
(
10
)
(2200)
(1800)
50
100
10
0
20
30
40
0
1000
2000
3000
15
30
Peak running range
Continuous running range
(
30.4
)
(
11.9
)
(
5
)
(1800)
(1800)
50
100
10
0
20
30
40
0
1000
2000
3000
25
50
Peak running range
Continuous running range
(
54.9
)
(
21.5
)
(
10
)
(1800)
(2600)
50
100
10
0
20
30
40
0
1000
2000
3000
10
20
Peak running range
Continuous running range
(
21.5
)
(
7.16
)
(
4.8
)
(
14
)
(2200) (2600)
*
These are subject to change. Contact us when you use these values for your machine design.
MFME series
(1.5kW to 4.5kW)
With oil seal
0)0(
*
1
*
Input voltage to driver: AC200V
(Dotted line represents torque at 10% less voltage.)
0)0(
*
1
*
Input voltage to driver: AC200V
(Dotted line represents torque at 10% less voltage.)
0)0(
*
1
*
Input voltage to driver: AC200V
(Dotted line represents torque at 10% less voltage.)
* Continuous torque vs. ambient temp.
* Continuous torque vs. ambient temp.
* Continuous torque vs. ambient temp.
ratio vs. rated torque
[%]
ambient temp. [°C]
torque
[N·m]
speed [r/min]
ratio vs. rated torque
[%]
ambient temp. [°C]
torque
[N·m]
speed [r/min]
ratio vs. rated torque
[%]
ambient temp. [°C]
torque
[N·m]
speed [r/min]
0)0(
*
1
*
Input voltage to driver: AC400V
(Dotted line represents torque at 10% less voltage.)
0)0(
*
1
*
Input voltage to driver: AC400V
(Dotted line represents torque at 10% less voltage.)
0)0(
*
1
*
Input voltage to driver: AC400V
(Dotted line represents torque at 10% less voltage.)
* Continuous torque vs. ambient temp.
* Continuous torque vs. ambient temp.
* Continuous torque vs. ambient temp.
ratio vs. rated torque
[%]
ambient temp. [°C]
torque
[N·m]
speed [r/min]
ratio vs. rated torque
[%]
ambient temp. [°C]
torque
[N·m]
speed [r/min]
ratio vs. rated torque
[%]
ambient temp. [°C]
torque
[N·m]
speed [r/min]
:KHQ\RXORZHUWKHWRUTXHOLPLWVHWXS3DQG
running range at high speed might be lowered as well.
torque
speed
Continuous running range
Running range (Torque limit setup : 300%)
Running range (Torque limit setup : 200%)
Running range (Torque limit setup : 100%)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for MINAS A5 Series
Page 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...