3-21
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
3. Wiring Diagram to the connector, X4
Connecting Example to Host Controller
Note
5HODWHGSDJH
UHSUHVHQWVWZLVWHGSDLUZLUH
3´,QSXWVDQGRXWSXWVRQFRQQHFWRU;µ
Connection between MINAS A5 and FPG-PP12 AFPG432 (Panasonic Electric Works)
to
PLC I/O
input
Counter clear input
Servo-ON input
Servo-Ready output
Servo-Alarm output
Positioning complete
output
Alarm clear input
Inhibit negative direction
travel input
Inhibit positive direction
travel input
Z-phase output
Gain switching input
CW pulse command
output
CCW pulse command
output
Origin input
Deviation counter
reset output
External power supply
input
Origin proximity input
from
PLC I/O
output
to
PLC I/O
input
GND
+ 24V
DC24V
Power supply
CW limit sensor
Origin proximity sensor
CCW limit sensor
A5-series
FPG-PP12 AFPG432
(Panasonic Electric Works)
Driver
PLC
Command pulse
input 2
Command sign
input 2
* Process of shield wire varies with equipment.
50
3
4
5
6
23
24
13,25
7
30
29
27
31
9
8
35
34
37
36
39
38
41
FG
PULS1
PULS2
SIGN1
SIGN2
OZ+
OZ−
GND
COM+
CL
SRV-ON
GAIN
A-CLR
POT
NOT
S-RDY+
S-RDY−
ALM+
ALM−
INP+
INP−
COM−
220Ω
220Ω
4.7Ω
4.7Ω
4.7Ω
4.7Ω
4.7Ω
4.7Ω
560Ω
6.8kΩ
FG
FG
+24VDC
GND
A1
B1
A2
B2
A4
B3
A7
B7
B4
A5
A19
B19
A20
B20
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for MINAS A5 Series
Page 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...