2-80
Parametr
No.
Title
Range
Default
Unit
Turning
on of
power
supply
Related
Control Mode Detail
page
Class No.
A,B
-frame
C
-frame
D,E,F
-frame
G,H
-frame
P
S
T
F
5
10
Sequence at alarm
0 to 7
0
ï
○ ○ ○ ○
4-45
5
11
Torque setup for emergency stop
0 to 500
0
%
○ ○ ○ ○
4-46
5
12
Over-load level setup
0 to 500
0
%
○ ○ ○ ○
5
13
Over-speed level setup
0 to 20000
0
r/min
○ ○ ○ ○
5
14
Motor working range setup
0 to 1000
10
0.1
revolution
*
○
○
5
15
,)UHDGLQJÀOWHU
0 to 3
0
ï
○
○ ○ ○ ○
5
16
Alarm clear input setup
0 to 1
0
ï
○
○ ○ ○ ○
4-47
5
17
Counter clear input mode
0 to 4
3
ï
○
○
5
18
Invalidation of command pulse inhibit
input
0 to 1
1
ï
○
○
5
19
Command pulse inhibit input reading
setup
0 to 4
0
ï
○
○
○
5
20
Position setup unit select
0 to 1
0
ï
○
○
○
4-48
5
21
Selection of torque limit
0 to 6
1
ï
○ ○
○
5
22
2nd torque limit
0 to 500
500
*
1
%
○ ○
○
5
23
Torque limit switching setup 1
0 to 4000
0
ms/100%
○ ○
○
4-49
5
24
Torque limit switching setup 2
0 to 4000
0
ms/100%
○ ○
○
5
25
External input positive direction
torque limit
0 to 500
500
*
1
%
○ ○
○
5
26
External input negative direction
torque limit
0 to 500
500
*
1
%
○ ○
○
5
27
Input gain of analog torque limit
10 to 100
30
0.1V/100%
*
○ ○
○
5
28
LED initial status
0 to 35
1
ï
○
○ ○ ○ ○
4-50
5
29
RS232 baud rate setup
0 to 6
2
ï
○
○ ○ ○ ○
5
30
RS485 baud rate setup
0 to 6
2
ï
○
○ ○ ○ ○
5
31
Axis address
0 to 127
1
ï
○
○ ○ ○ ○
4-51
5
32
Command pulse input maximum
setup
250 to 4000
4000
kpulse/s
○
○
○
5
33
Pulse regenerative output limit setup
0 to 1
0
ï
○
○ ○ ○ ○
5
34
For manufactuer's use
ï
4
ï
5
35
Front panel lock setup
0 to 1
0
ï
○
○ ○ ○ ○
'HÀQLWLRQRIV\PEROVXQGHU´3RZHU2II2QµLIDFKDQJHLVPDGHLWZLOOEHUHÁHFWHGXSRQWKHSDUDPHWHUZKHQWKH
power to the driver is turned off and then on again.
*
'HÀQLWLRQRIV\PEROVXQGHU´5HODWHGPRGHµ3SRVLWLRQFRQWURO6YHORFLW\FRQWURO7WRUTXHFRQWURO)IXOOFORVHGFRQWURO
*1 Default settings depend on the combination of driver and motor. Refer to P. 2-82 “Torque limit setting”.
13. Setup of Parameter and Mode
List of Parameters
Caution
Note
The symbol “
*
” attached to “Unit”. indicates that the digits of setting unit will change if the
parameter is set by using the setup support software PANATERM.
Parameter describes of this page is P.4-45 to P.4-51.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for MINAS A5 Series
Page 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...