6-3
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
Note
+LVWRU\7KHHUURUZLOOEHVWRUHGLQWKHHUURUKLVWRU\
Can be cleared...To cancel the error, use the alarm clear input (A-CLR).
If the alarm clear input is not effective, turn off power, remove the cause of the error and then turn on
power again.
Immediate stop...Instantaneous controlled stop upon occurrence of an error.
6HWWLQJRI´3U6HTXHQFHDWDODUPµLVDOVRUHTXLUHG
<List of error code No.>
Error code
Protective function
Attribute
Detail
page
Main Sub
History
Can be
cleared
Immediate
stop
11
Control power supply under-
voltage protection
6-4
12
Over-voltage protection
13
Main power supply under-volt-
age protection (between P and N)
1
Main power supply under-
voltage protection
(AC interception detection)
14
Over-current protection
6-5
1
IPM error protection
15
Over-heat protection
16
Over-load protection
6-6
18
Over-regeneration load protection
1
Over-regeneration Tr error
protection
6-7
21
Encoder communication dis-
connect error protection
1
Encoder communication error
protection
23
Encoder communication data
error protection
24
Position deviation excess pro-
tection
1
Velocity deviation excess pro-
tection
25
+\EULGGHYLDWLRQH[FHVVHUURU
protection
6-8
26
Over-speed protection
1
2nd over-speed protection
27
Command pulse input frequen-
cy error protection
2
Command pulse multiplier error
protection
28
Limit of pulse replay error pro-
tection
'HYLDWLRQFRXQWHURYHUÁRZ
protection
Safety detection
33
IF overlaps allocation error 1
protection
1
IF overlaps allocation error 2
protection
2
IF input function number error 1
protection
3
IF input function number error 2
protection
4
IF output function number error
1 protection
5
IF output function number error
2 protection
6
&/ÀWWLQJHUURUSURWHFWLRQ
7
,1+ÀWWLQJHUURUSURWHFWLRQ
1. When in Trouble
Protective Function (What is Error Code ?)
Error code
Protective function
Attribute
Detail
page
Main Sub
History
Can be
cleared
Immediate
stop
34
Software limit protection
36
WR
2
EEPROM parameter error pro-
tection
37
WR
2
EEPROM check code error
protection
38
Over-travel inhibit input protection
Analog input1 excess protection
1
Analog input2 excess protection
2
Analog input3 excess protection
Absolute system down error
protection
6-11
41
Absolute counter over error
protection
42
Absolute over-speed error pro-
tection
43
Initialization failure
44
Absolute single turn counter
error protection
45
Absolute multi-turn counter er-
ror protection
47
Absolute status error protection
48
Encoder Z-phase error protection
Encoder CS signal error protection
6-12
Feedback scale connection er-
ror protection
1
Feedback scale communication
error protection
51
)HHGEDFNVFDOHVWDWXVHUURU
protection
1
Feedback scale status 1 error
protection
2
Feedback scale status 2 error
protection
3
Feedback scale status 3 error
protection
4
Feedback scale status 4 error
protection
5
Feedback scale status 5 error
protection
55
A-phase connection error protection
6-13
1
B-phase connection error protection
2
Z-phase connection error protection
87
Compulsory alarm input protection
WR
Motor automatic recognition
error protection
Other error
Other
number
Note
2QO\IRUSRVLWLRQFRQWUROW\SHLVQRWSURYLGHGZLWK;;;
and analog input.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for MINAS A5 Series
Page 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...