3-24
3. Wiring Diagram to the connector, X4
Connecting Example to Host Controller
Connection between MINAS A5 and F3YP14-ON/F3YP18-ON (Yokogawa Electric Corp.)
Note
5HODWHGSDJH
UHSUHVHQWVWZLVWHGSDLUZLUH
3´,QSXWVDQGRXWSXWVRQFRQQHFWRU;µ
Command pulse
input 2
Counter clear input
Servo-ON input
Servo-Ready output
Servo-Alarm output
Positioning complete
output
Alarm clear input
Inhibit negative direction
travel input
Inhibit positive direction
travel input
Z-phase output
Command sign
input 2
Gain switching input
from
PLC I/O
output
to
PLC I/O
input
CCW limit sensor
Origin proximity sensor
CW limit sensor
A5-series
F3YP14-ON/F3YP18-ON
(Yokogawa Electric Corp.)
Driver
PLC
CW pulse command
output
CCW pulse command
output
Origin line driver
input
Deviation counter
reset output
5V power supply
for pulse output
Origin proximity input
CW limit input
CCW limit input
* Process of shield wire varies with equipment.
14a
13a
12a
11a
15a
16a
10a
9a
8b
8a
1a
3a
2a
4a
+V
GND
50
3
4
5
6
23
24
13,25
7
30
29
27
31
9
8
35
34
37
36
39
38
41
FG
PULS1
PULS2
SIGN1
SIGN2
OZ+
OZ−
GND
COM+
CL
SRV-ON
GAIN
A-CLR
POT
NOT
S-RDY+
S-RDY−
ALM+
ALM−
INP+
INP−
COM−
220Ω
220Ω
4.7Ω
4.7Ω
4.7Ω
4.7Ω
4.7Ω
4.7Ω
240
Ω
7.4kΩ
7.4kΩ
7.4kΩ
GND
+ 24V
DC24V
Power supply
GND
+ 5V
DC5V
Power supply
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for MINAS A5 Series
Page 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...