2-2
2
Preparation
1. Conformance to international standards
EC Directives
EC Directives
7KH(&'LUHFWLYHVDSSO\WRDOOVXFKHOHFWURQLFSURGXFWVDVWKRVHKDYLQJVSHFLÀFIXQFWLRQV
and have been exported to EU and directly sold to general consumers. Those products
DUHUHTXLUHGWRFRQIRUPWRWKH(8XQLÀHGVWDQGDUGVDQGWRIXUQLVKWKH&(PDUNLQJRQWKH
products.
However, our AC servos meet the relevant EC Directives for Low Voltage Equipment so
that the machine or equipment comprising our AC servos can meet EC Directives.
EMC Directives
MINAS Servo System conforms to relevant standard under EMC Directives setting up
certain model (condition) with certain locating distance and wiring of the servo motor and
the driver. And actual working condition often differs from this model condition especially
in wiring and grounding. Therefore, in order for the machine to conform to the EMC Di-
rectives, especially for noise emission and noise terminal voltage, it is necessary to ex-
amine the machine incorporating our servos.
Conformity to UL Standards
Remarks
Note
Observe the following conditions of (1) and (2) to make the system conform to UL508C
(E164620).
(1) Use the driver in an environment of Pollution Degree 2 or 1 prescribed in IEC60664-1.
(e.g. Install in the control box with IP54 enclosure.)
(2) Make sure to install a circuit breaker or fuse which are UL recognized (Listed
PDUNHGEHWZHHQWKHSRZHUVXSSO\DQGWKHQRLVHÀOWHU
8VHDFRSSHUFDEOHZLWKWHPSHUDWXUHUDWLQJRIÝ&RUKLJKHU
For rated current of circuit breaker and fuse, refer to P.2-10 “Driver and List of Appli-
cable Peripheral Equipments”.
(3) Over-load protection level
Over-load protective function will be activated when the effective current exceeds
115% or more than the rated current based on the time characteristics (see the next
SDJH&RQÀUPWKDWWKHHIIHFWLYHFXUUHQWRIWKHGULYHUGRHVQRWH[FHHGWKHUDWHGFXU
-
rent. Set up the peak permissible current with Pr0.13 (Setup of 1st torque limit) and
Pr5.22 (Setup 2nd torque limit).
SEMI F47
Caution
,QFOXGHVDIXQFWLRQLQFRPSOLDQFHZLWKWKH6(0,)VWDQGDUGIRUYROWDJHVDJLPPXQLW\
under no load or light load.
,GHDOIRUWKHVHPLFRQGXFWRUDQG/&'LQGXVWULHV
(1) Excluding the single-phase 100-V type.
(2) Please verify the actual compliance of your machine with the F47 standard for volt-
age sag immunity.
Note
For Overload protection time characterstics, refer to P.6-14.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for MINAS A5 Series
Page 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...