2-83
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
Cautions on Replacing the Motor
As stated previously, torque limit setup range might change when you replace the combi-
nation of the motor and the driver. Pay attention to the followings.
:KHQWKHPRWRUWRUTXHLVOLPLWHG
When you replace the motor series or to the different wattage motor, you need to reset
the torque limit setup because the rated toque of the motor is different from the previ-
ous motor. (see e.g.1)
:KHQ\RXZDQWWRREWDLQWKHPD[PRWRUWRUTXH
<RXQHHGWRUHVHWWKHWRUTXHOLPLWLQJVHWXSWRWKHXSSHUOLPLWEHFDXVHWKHXSSHUOLPLW
value might be different from the previous motor. (see e.g.2)
e.g.1)
Pr0.13 Setup range : 0 to 300%
Setup value : 100%.
before replacing the motor
Rated torque
0.64N
m
Rated torque
0.32N
m
MADHT1507
MSME022S1A
Pr0.13 Setup range : Change to 0 to 300%.
Setup value : Keep 100%.
after replacing the motor
MADHT1507
MSME012S1A
Torque limit value
0.32N
m
0.32N
m x 100% =
Torque limit value
0.64N
m
0.64N
m x 100% =
Set up Pr0.13 to 200 to
make torque limit value
to 0.64N
m
(0.32N
m x 200% = 0.64N
m)
MADHT1507
MADHT1507
MSME022S1A
MSME012S1A
e.g.2)
before replacing the motor
after replacing the motor
Pr0.13 Setup range : 0 to 300%
Setup value : 300%.
Pr0.13 Setup range : change to 0 to 300%
Setup value : Keep 300%.
Rated torque
0.32N
m
Set up Pr0.13 to 300 to obtain
the max. output torque.
13. Setup of Parameter and Mode
6HWXSRI7RUTXH/LPLW
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for MINAS A5 Series
Page 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...