27 Troubleshooting
E610–E613
Cause:
The marking data are out of range.
Remedy:
• Check the marking image display and adjust position and size of the
marking data.
• Adjust the values for “X-axis offset [mm]” and “Y-axis offset [mm]” in
“System settings” > “System offset”. The system offset values are not
reflected in the marking image editor.
E614–E615
Cause:
The z-position of the marking data is outside the marking area.
Remedy:
• Adjust the value for z-movement in the object group settings.
• Adjust the value for z-movement in the file settings.
• Adjust the value for “Z-axis offset [mm]” in “System settings” >
“System offset”.
Applies to LP-GS only.
E616
Cause:
The signals from the encoder are invalid. The line speed cannot be
detected.
Remedy:
• Check the signal transmission from the encoder to ENCODER A IN
(X13) and ENCODER B IN (X14) of the TERMINAL connector.
• If either phase A or B of the encoder is used, connect the encoder
to ENCODER A IN (X13) and connect ENCODER B IN (X14) to IN
COM. 1 (X2).
• Make sure the encoder frequency does not exceed 100kHz per
phase.
Applies to LP-RC, LP-RF, LP-RV only.
E617
Cause:
The marking speed cannot follow the line speed.
Remedy:
• Decrease the line speed.
• Specify an upstream position (positive value) for the lasing start
boundary.
• Reduce the marking time by increasing the scan speed, reducing the
space between characters, reducing the character size, etc.
Applies to LP-RC, LP-RF, LP-RV only.
ME-NAVIS2-OP-1