27 Troubleshooting
Related topics
Reset an alarm message (E001–E599)
27.13 Warning messages E600–E799
Error codes in the range from E600 to E799 indicate a warning.
E600
Cause:
The laser stop input is open.
Remedy:
• Connect the LASER STOP IN inputs on the TERMINAL connector.
• Check the status of the safeguards connected to the LASER STOP
IN inputs.
• Check the operation logic of the connected device.
E601
Cause:
The specified file contains no marking data.
Remedy:
Add the marking data and overwrite the file.
E603
Cause:
No data is available for laser radiation.
Remedy:
It is not possible to input a marking trigger signal if the marking file does
not contain valid marking data. Turn on the marking for at least one
marking object and select a laser power correction other than 0%.
E604
Cause:
No data are available for guide laser radiation.
Remedy:
To show masked objects with the guide laser, enable guide laser display
in the object settings.
ME-NAVIS2-OP-1
333