24 System settings
• Specify whether you want to control laser pumping, shutter operation, and guide
laser display by I/O signals or by communication commands.
For “Laser pumping control”, “Shutter control” and “Guide laser display control” (LP-
GS051, LP-GS051-L, LP-RC350S, LP-RF, LP-RV), select “I/O” or “Communication
commands”.
The initial setting is “I/O”.
LP-RF, LP-RV: Select “I/O” to control laser pumping, shutter operation, and guide
laser display via optional network unit (EtherNet/IP or PROFINET).
• “INTERLOCK alarm detection”: Specify when an alarm should be detected.
This setting is for the alarm of the interlock functions controlled by I/O signals
INTERLOCK 1 (X16, X17), INTERLOCK 2 (X18, X19) and REMOTE INTERLOCK IN
(X20, for LP-RC, LP-RF, LP-RV).
‒ “Activate always under remote mode” (initial setting)
‒ “Deactivate while shutter closed”:
With this setting, no alarm is output if you open the interlock connections and
the shutter is closed. If you want to use a guide laser in remote mode, set
“Deactivate while shutter closed” for “INTERLOCK alarm detection”.
4. Select “Apply to laser marking system” in the ribbon.
5. Disconnect the online connection with the laser marking system.
6. Turn off the power of the laser marking system, wait five seconds and then restart the
system.
Do not turn off the power supply during an online connection with your PC. Otherwise a data loss or
system failure may occur.
The new settings will be updated in the laser marking system.
Related topics
Specify input and output settings
24.7 Specify settings for the controller LED display
Specify the controller LED display settings, including the backlight color and the display
language. These settings are available for LP-RC, LP-RF and LP-RV.
You can specify different colors that indicate normal operation, alarm or warning output.
258