22 Laser settings
“Laser power correction [%]” for one point: The laser power is set by multiplying the
laser power correction ratio set for the point and the laser power value set in “Laser
settings”.
‒ GS1 DataBar Limited CC-A, GS1 DataBar Stacked CC-A: Specifies the laser power
for the 1D part of the code.
• “Scan speed correction [%]”:
To correct the scan speed, enter a value in the text box.
‒ GS1 DataBar Limited CC-A, GS1 DataBar Stacked CC-A: Specifies the scan speed
for the 1D part of the code.
• “Pulse cycle correction [%]” (LP-RF, LP-RV):
To correct the pulse cycle, enter a value in the text box.
‒ Point radiation objects: The pulse cycle of all points in the selected object is adjusted.
‒ GS1 DataBar Limited CC-A, GS1 DataBar Stacked CC-A: Specifies the pulse cycle
for the 1D part of the code.
GS1 DataBar Limited CC-A, GS1 DataBar Stacked CC-A: Under “Laser correction (2D)”,
specify laser correction parameters for the 2D part of the code and the separator between
the 1D and 2D part.
• For the 2D part of the code, you can specify values for “Laser power correction [%]”,
“Scan speed correction [%]” and “Pulse cycle correction [%]” (LP-RF, LP-RV).
• For the separator, you can set values for “Laser power correction (separator) [%]”, “Scan
speed correction (separator) [%]” and “Pulse cycle correction (separator) [%]” (LP-RF, LP-
RV).
Note
• Marking is not possible if the laser power correction value is 0.
• If the corrected value exceeds the allowable limit, the marking is performed with the
maximum or minimum parameter value. The correction ratio is calculated based on the
value set as 100% in “Laser settings”.
• For bar code or 2D code objects, you can fine-tune the time until the laser starts radiating
at the start or end point in “Laser settings” under “Customize starting/ending point by
object”.
Related topics
Set laser correction parameters for code elements
ME-NAVIS2-OP-1
239