![Omron ZW-7000 Series User Manual Download Page 219](http://html1.mh-extra.com/html/omron/zw-7000-series/zw-7000-series_user-manual_742279219.webp)
Search from Menu Tree
ZW-8000/7000/5000
User's Manual
217
7
Senso
r con
trol
ler
ope
ra
ti
ons
* default value
Setting
Option/Setting Range
Pages
I/O setting
[I/O]
Digital output
[DIGTAL]
Output data 3
[OUT3]
OFF[OFF] / TASK1 [TASK1] / TASK2
[TASK2] / TASK3 [TASK3]* / TASK4
[TASK4] /Amount of emitted light
[LIGHT] (Area1) / Peak amount of
received light (Exposure control edge)
[PEAK.CT] (Area1) / Peak amount of
received light (1st surface) [PEAK.1]
(Area1) / Peak amount of received
light (2nd surface) [PEAK.2] (Area1) /
Peak amount of received light (3rd
surface) [PEAK.3] (Area1) / Peak
amount of received light (4th surface)
[PEAK.4] (Area1) Amount of emitted
light [LIGHT] (Area2) / Peak amount
of received light (Exposure control
edge) [2.PEAK.C] (Area2) / Peak
amount of received light (1st surface)
[2.PEAK.1] (Area2) / Peak amount of
received light (2nd surface)
[2.PEAK.2] (Area2) / Peak amount of
received light (3rd surface)
[2.PEAK.3] (Area2) / Peak amount of
received light (4th surface)
[2.PEAK.4] (Area2)
Measurement state[MS.CON] (ZW-
8000
@
only)
Area1 Reflection
power[REF.PW1](ZW-8000
@
only)/
Area2 Reflection
power[REF.PW2](ZW-8000
@
only)
*1
(cont'd)
Output data 4
[OUT4]
OFF[OFF] / TASK1 [TASK1] / TASK2
[TASK2] / TASK3 [TASK3] / TASK4
[TASK4]* /Amount of emitted light
[LIGHT] (Area1) / Peak amount of
received light (Exposure control edge)
[PEAK.CT] (Area1) / Peak amount of
received light (1st surface) [PEAK.1]
(Area1) / Peak amount of received
light (2nd surface) [PEAK.2] (Area1) /
Peak amount of received light (3rd
surface) [PEAK.3] (Area1) / Peak
amount of received light (4th surface)
[PEAK.4] (Area1) Amount of emitted
light [LIGHT] (Area2) / Peak amount
of received light (Exposure control
edge) [2.PEAK.C] (Area2) / Peak
amount of received light (1st surface)
[2.PEAK.1] (Area2) / Peak amount of
received light (2nd surface)
[2.PEAK.2] (Area2) / Peak amount of
received light (3rd surface)
[2.PEAK.3] (Area2) / Peak amount of
received light (4th surface)
[2.PEAK.4] (Area2)
Measurement state[MS.CON] (ZW-
8000
@
only)
Area1 Reflection
power[REF.PW1](ZW-8000
@
only)/
Area2 Reflection
power[REF.PW2](ZW-8000
@
only)
*1
Clamp value
[CLAMP]
0x7FFFFFFF[MAX] /
999999999[99999] / 0 [0] /
-999999999 [-99999] /
0x80000000[MIN]*
*1
*1. For more detail, refer to the following.
“6-1 Connecting Parallel I/O” described in Displacement Sensor ZW-8000/7000/5000 series Confocal Fiber Type
Displacement Sensor User’s Manual for Communications Settings (Z363)
Summary of Contents for ZW-7000 Series
Page 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Page 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Page 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Page 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Page 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Page 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Page 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Page 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Page 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Page 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Page 335: ......