Setting I/O
ZW-8000/7000/5000
User's Manual
177
4
Settin
gs for Function
Setting the non-measurement conditions
The measurement value can be set to the clamp value when there is an unexpected number of edges or
reflection power due to the state of the light reception waveform.
At this time, "------" is displayed on the controller's main display.
* With ZW-7000
@
/5000
@
, this setting is not possible.
Multi View Explore
: [Bank Group] | [(Bank Data Name)] (double click)
→
Edit pane
: [I/O Settings] icon (
)
→
I/O Setting Screen
: [Non-Measuring Specification]
Setting item
Setting value
Description
Reflection power ON/OFF
When set to ON, the measurement value
is set to the clamp value when less than
the set reflection power threshold.
Reflective power
threshold
1 to 1000
Set the reflection power threshold value.
Reflection power is the strength of light
returning from the workpiece.
Number of Edge ON/OFF
When set to ON, if the set edge number
condition is not met, the measurement
value is set to the clamp value.
Condition for
number of Edge
surface/ 2 surface /3 surface /4 surface /Edge 5 or more
Set the edge number condition.
Comparison
condition of
number of Edge
(Condition for number of Edge) = (Observed number of Edge)/
(Condition for number of Edge)
≤
(Observed number of Edge)/
(Condition for number of Edge)
≥
(Observed number of Edge)
Set the edge number comparison
condition.
1
Set the operating mode to the FUNC mode.
3-2 Switching operation modes p.98
2
Set the condition of the non-measurement
value at [Non-Measuring Specification].
3
Set [Reflective power threshold], [Condition for number of Edge] and [Comparison condition of
number of Edge].
Summary of Contents for ZW-7000 Series
Page 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Page 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Page 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Page 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Page 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Page 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Page 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Page 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Page 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Page 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Page 335: ......