![Omron ZW-7000 Series User Manual Download Page 181](http://html1.mh-extra.com/html/omron/zw-7000-series/zw-7000-series_user-manual_742279181.webp)
Setting I/O
ZW-8000/7000/5000
User's Manual
179
4
Settin
gs for Function
Settings for Processing When Measurement Is Not Possible
Setting operation when measurement is not possible
Set the output method when the sensor head temporarily enters a non-measurement state, for example, due to
insufficient received light amount.
With ZW-8000
@
, the keep count and restore from clamp value count can be specified.
With ZW-7000
@
/5000
@
, the keep count and restore from clamp value count cannot be specified.
Example: When skipping occurs in the measurement values due to low incident level
• When performing hold measurement, the output before the initial hold value is applied is the same as that for
“Clamp” even if “Keep” is set.
• When performing hold measurement, the keep count and restore from non-measurement state count cannot be
specified.
Item
Setting item
Setting value
Description
Non-Measure-
ment setting
Mode
Clamp
With analog output, the preset clamp value (abnormal
value) is output. All judgment outputs become OFF.
Keep
The measured value before the non-measurement state
was entered is held and output.
Keep count
specification flag
ON
Specifies the keep count and restore from clamp value
count. The mode setting is enabled during keeping.
* This setting cannot be used with ZW-7000
@
/5000
@
.
OFF
The immediately preceding measurement value is held and
output, regardless of the non-measurement state count.
* This setting cannot be used with ZW-7000
@
/5000
@
.
Keep count
1 to 16382
Sets the keep count of the immediately preceding
measurement value during non-measurement.
* This setting cannot be used with ZW-7000
@
/5000
@
.
Number of
restorations
1 to 16382
Sets the count of restorations from non-measurement state
to measurement state.
* This setting cannot be used with ZW-7000
@
/5000
@
.
(1)
(1)
(2)
(2)
(
3
)
(
3
)
Direction of
workpiece
movement
Amo
u
nt of di
s
pl
a
cement
Amo
u
nt of di
s
pl
a
cement
S
kipping h
as
occ
u
rred d
u
e to low
incident level
A
s
the v
a
l
u
e
b
efore
s
kipping occ
u
r
s
i
s
kept, thi
s
i
s
effective in c
a
nceling me
asu
rement v
a
l
u
e
s
kipping.
When [Keep] i
s
s
elected
Important
Summary of Contents for ZW-7000 Series
Page 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Page 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Page 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Page 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Page 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Page 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Page 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Page 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Page 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Page 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Page 335: ......