![Omron ZW-7000 Series User Manual Download Page 140](http://html1.mh-extra.com/html/omron/zw-7000-series/zw-7000-series_user-manual_742279140.webp)
Setting Measurement Items
138
ZW-8000/7000/5000
User's Manual
4-2 Setting Measurement Items
What is a Measurement Item?
Obtain the waveform data based on the specified sensing condition, and calculate the height/thickness of up to
four surfaces included in the measuring range. Perform calculations using the output result of each task.
Count the measurement surface closest to the Sensor Head first (default value).
Measuring the Height
The count direction for measurement surfaces can be changed.
Setting Start Direction of Count Measurement Surfaces p.128
Sensor head
Edge 1st
Edge 2nd
Edge 3rd
Edge 4th
Note
The setting for common height
measurements as shown in the
following diagram is registered
for TASK1 in advance. In such
a case, this setting is not required.
Set this item when measuring
the height of an object below
a transparent object as shown
in the following diagram.
Edge 1st
Height
Edge 1st
Edge 2nd
Measurement
range
Transparent
object
Sensor head
Sensor head
Summary of Contents for ZW-7000 Series
Page 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Page 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Page 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Page 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Page 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Page 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Page 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Page 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Page 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Page 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Page 335: ......