Gearmotor
The speed range for continuous operation differs according to the lubrication method
and motor manufacturer. In particular, the continuous operation of an oil-lubricated mo-
tor in the low speed range may result in burning. If the motor is to be operated at a speed
higher than 60 Hz, consult with the manufacturer.
D
Synchronous Motor
A synchronous motor is not suitable for Inverter control.
If a group of synchronous motors is individually turned on and off, synchronism may be
lost.
D
Single-phase Motor
Do not use the Inverter for a single-phase motor.
The motor should be replaced with a 3-phase motor.
H
Power Transmission Mechanism (Speed Reducers, Belts, and
Chains)
If an oil-lubricated gear box or speed reducer is used in the power transmission mecha-
nism, oil lubrication will be affected when the motor operates only in the low speed
range. The power transmission mechanism will make noise and experience problems
with service life and durability if the motor is operated at a speed higher than 60 Hz.
H
Motor Burnout Caused by Insufficient Dielectric Strength of
Each Phase of Motor
Surge occurs among the phases of the motor when the output voltage is switched.
If the dielectric strength of each phase of the motor is insufficient, the motor may burn
out.
The dielectric strength of each phase of the motor must be higher than the maximum
surge voltage. Normally, the maximum surge voltage is approximately three times the
power voltage imposed on the Inverter.
Using Inverter for Motor
Chapter 10
Summary of Contents for SYSDRIVE 3G3JV-AB001
Page 1: ...USER S MANUAL FIRST DRAFT SYSDRIVE 3G3JV Compact Simplified Inverter Cat No I528 E1 1...
Page 3: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Page 9: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 43: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Page 52: ...3 10 Preparing for Operation and Monitoring Chapter 3...
Page 53: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 62: ...4 10 Test Run Chapter 4...
Page 131: ...7 22 Maintenance Operations Chapter 7...
Page 132: ...Chapter 8 Specifications 8 1 Inverter Specifications 8 2 Option Specifications 8...
Page 138: ...Chapter 9 List of Parameters 9...
Page 150: ...Chapter 10 Using the Inverter for a Motor 10...
Page 165: ...Revision History 10 2...
Page 166: ...Cat No I528 E1 1 SYSDRIVE 3G3JV Compact Simplified Inverter USER S MANUAL...