![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3jv-ab001/sysdrive-3g3jv-ab001_user-manual_742834133.webp)
8-2
8-1
Inverter Specifications
3-phase
200 VAC
Model 3G3JV-
A2001
A2002
A2004
A2007
A2015
A2022
3 phase
200-VAC
models
Power
supply
Rated voltage
and frequency
3-phase 200 to 230 VAC at 50/60 Hz
supply
Allowable voltage
fluctuation
–15% to 10%
Allowable
frequency
fluctuation
±
5%
Heat radiation (W)
13.0
18.0
28.1
45.1
72.8
86.5
Weight (kg)
0.5
0.5
0.8
0.9
1.3
1.5
Cooling method
Natural cooling
Cooling fan
Single-
h
Model 3G3JV-
AB001
AB002
AB004
AB007
AB015
---
Single
phase
200-VAC
models
Power
supply
Rated voltage
and frequency
Single-phase 200 to 240 VAC at 50/60 Hz
models
supply
Allowable voltage
fluctuation
–15% to 10%
Allowable
frequency
fluctuation
±
5%
Heat radiation (W)
13.0
18.0
28.1
45.1
72.8
---
Weight (kg)
0.5
0.5
0.9
1.5
1.5
---
Cooling method
Natural cooling
Cooling fan
Max. applicable motor capacity (kW)
0.1
0.2
0.4
0.75
1.5
2.2
Output
specifi-
i
Rated output capacity
(kVA)
0.3
0.6
1.1
1.9
3.0
4.2
specifi
cations
Rated output current (A)
0.8
1.6
3.0
5.0
8.0
11.0
Rated output voltage (V)
3-phase 200 to 240 VAC (according to the input voltage)
Max. output frequency
400 Hz parameter setting
Control
charac-
i i
Harmonic-current
countermeasures
DC reactor (option) connection possible
charac
teristics
Control method
Sine wave PWM (V/f control)
Carrier frequency
2.5 to 10.0 kHz (in vector control)
Frequency control range
0.1 to 400 Hz
Frequency precision
(temperature
characteristics)
Digital commands:
±
0.01% (–10
°
C to 50
°
C)
Analog commands:
±
0.5% (25
°
C
±
10
°
C)
Frequency setting
resolution
Digital commands: 0.1 Hz (less than 100 Hz) and 1 Hz
(100 Hz or over)
Analog commands: 0.06 Hz/60 Hz (equivalent to 1/1000)
Output frequency
resolution
0.01 Hz
Specifications
Chapter 8
Summary of Contents for SYSDRIVE 3G3JV-AB001
Page 1: ...USER S MANUAL FIRST DRAFT SYSDRIVE 3G3JV Compact Simplified Inverter Cat No I528 E1 1...
Page 3: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Page 9: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 43: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Page 52: ...3 10 Preparing for Operation and Monitoring Chapter 3...
Page 53: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 62: ...4 10 Test Run Chapter 4...
Page 131: ...7 22 Maintenance Operations Chapter 7...
Page 132: ...Chapter 8 Specifications 8 1 Inverter Specifications 8 2 Option Specifications 8...
Page 138: ...Chapter 9 List of Parameters 9...
Page 150: ...Chapter 10 Using the Inverter for a Motor 10...
Page 165: ...Revision History 10 2...
Page 166: ...Cat No I528 E1 1 SYSDRIVE 3G3JV Compact Simplified Inverter USER S MANUAL...