6-5
6-2
DC Injection Braking Function
The DC injection braking function applies DC on the induction motor for
braking control.
Startup DC Injection Braking:
This braking is used for stopping and starting the motor rotating by inertia
with no regenerative processing.
DC Injection Braking to Stop:
Adjust the stop DC injection braking time if the motor rotating does not
decelerate to a stop in normal operation due to inertia from a heavy load.
By increasing the DC injection braking time or DC injection braking current,
the time required for stopping the motor is reduced.
n52
DC Injection Braking Current
Changes during
operation
No
Setting
range
0 to 100 (%)
Unit of
setting
1%
Default setting
50
n53
DC Injection Braking-to-stop Time
Changes during
operation
No
Setting
range
0.0 to 25.5 (s)
Unit of
setting
0.1 s
Default setting
0.5
n54
Startup DC Injection Braking Time
Changes during
operation
No
Setting
range
0.0 to 25.5 (s)
Unit of
setting
0.1 s
Default setting
0.0
•
Set the DC injection braking current as percentage based on the rated current of the
Inverter as 100%.
•
After the startup DC injection braking time is set, the Inverter starts up at minimum fre-
quency on completion of the startup DC injection braking control of the Inverter.
•
After the speed is reduced, the Inverter is switched to DC injection braking at minimum
output frequency.
DC Injection Braking Control
Output
frequency
Minimum
output
frequency
(n14)
n54
Startup DC injection
braking time
n53
DC injection
braking-to-stop time
Time
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3JV-AB001
Page 1: ...USER S MANUAL FIRST DRAFT SYSDRIVE 3G3JV Compact Simplified Inverter Cat No I528 E1 1...
Page 3: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Page 9: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 43: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Page 52: ...3 10 Preparing for Operation and Monitoring Chapter 3...
Page 53: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 62: ...4 10 Test Run Chapter 4...
Page 131: ...7 22 Maintenance Operations Chapter 7...
Page 132: ...Chapter 8 Specifications 8 1 Inverter Specifications 8 2 Option Specifications 8...
Page 138: ...Chapter 9 List of Parameters 9...
Page 150: ...Chapter 10 Using the Inverter for a Motor 10...
Page 165: ...Revision History 10 2...
Page 166: ...Cat No I528 E1 1 SYSDRIVE 3G3JV Compact Simplified Inverter USER S MANUAL...