![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3jv-ab001/sysdrive-3g3jv-ab001_user-manual_742834103.webp)
6-17
n48
Number of Fault Retries
Changes during
operation
No
Setting
range
0 to 10
Unit of
setting
1
Default setting
0
Set Values
•
Set the number of fault retries required.
•
The count of fault retries will be cleared in any of the following cases.
The Inverter is normal for 10 minutes continuously after the latest fault retry was
made.
Power supply to the Inverter is interrupted.
A fault reset is input.
6-7-5 Frequency Jump Function (n49 to n51)
•
The frequency jump function prevents the Inverter from generating frequencies that
make the mechanical system resonate.
•
The frequency jump function can be used effectively to set two dead bands of a fre-
quency reference.
n49
Jump Frequency 1
Changes during
operation
No
Setting
range
0.0 to 400 (Hz)
Unit of
setting
0.1 Hz
(see note)
Default setting
0.0
n50
Jump Frequency 2
Changes during
operation
No
Setting
range
0.0 to 400 (Hz)
Setting
range
0.1 Hz
(see note)
Unit of setting
0.0
n51
Default Setting
Changes during
operation
No
Setting
range
0.0 to 25.5 (Hz)
Unit of
setting
0.1 Hz
Default setting
0.0
Note Values will be set in 0.1-Hz increments if the frequency is less than 100 Hz and
1-Hz increments if the frequency is 100 Hz or greater.
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3JV-AB001
Page 1: ...USER S MANUAL FIRST DRAFT SYSDRIVE 3G3JV Compact Simplified Inverter Cat No I528 E1 1...
Page 3: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Page 9: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 43: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Page 52: ...3 10 Preparing for Operation and Monitoring Chapter 3...
Page 53: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 62: ...4 10 Test Run Chapter 4...
Page 131: ...7 22 Maintenance Operations Chapter 7...
Page 132: ...Chapter 8 Specifications 8 1 Inverter Specifications 8 2 Option Specifications 8...
Page 138: ...Chapter 9 List of Parameters 9...
Page 150: ...Chapter 10 Using the Inverter for a Motor 10...
Page 165: ...Revision History 10 2...
Page 166: ...Cat No I528 E1 1 SYSDRIVE 3G3JV Compact Simplified Inverter USER S MANUAL...