![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3jv-ab001/sysdrive-3g3jv-ab001_user-manual_742834093.webp)
6-7
n56
Stall Prevention Level during
Acceleration
Changes during
operation
No
Setting
range
30 to 200 (%)
Unit of
setting
1%
Set Values
170
Set Values
•
This function is used to stop accelerating the load if the output current exceeds the set
current value so that the Inverter will continue operating without stalling. The Inverter
accelerates the load while the output current is the same as or less than the set value.
•
Set the parameter as percentage based on the rated Inverter current as 100%.
•
The default setting does not need any changes in normal operation.
•
Decrease the set value if the capacity of the motor is smaller than that of the Inverter or
the motor stalls with the default value.
The set value is normally 2 or 3 times higher than the rated current of the motor. Set this
current as percentage based on the rated inverter current as 100%.
Stall Prevention during Acceleration
Output
current
n56 (stall prevention level
during acceleration)
Time
Output
frequency
The output frequency is controlled
so that the Inverter will not stall.
Time
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3JV-AB001
Page 1: ...USER S MANUAL FIRST DRAFT SYSDRIVE 3G3JV Compact Simplified Inverter Cat No I528 E1 1...
Page 3: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Page 9: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 43: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Page 52: ...3 10 Preparing for Operation and Monitoring Chapter 3...
Page 53: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 62: ...4 10 Test Run Chapter 4...
Page 131: ...7 22 Maintenance Operations Chapter 7...
Page 132: ...Chapter 8 Specifications 8 1 Inverter Specifications 8 2 Option Specifications 8...
Page 138: ...Chapter 9 List of Parameters 9...
Page 150: ...Chapter 10 Using the Inverter for a Motor 10...
Page 165: ...Revision History 10 2...
Page 166: ...Cat No I528 E1 1 SYSDRIVE 3G3JV Compact Simplified Inverter USER S MANUAL...