6-10
n60
Overtorque Detection Level
Changes during
operation
No
Setting
range
30 to 200 (%)
Unit of
setting
1%
Default setting
160
Set Values
•
Set the parameter as percentage based on the rated Inverter current as 100%.
n61
Overtorque Detection Time
Changes during
operation
No
Setting
range
0.1 to 10.0 (s)
Unit of
setting
0.1 s
Default setting
0.1
Set Values
•
Set the overtorque detection time.
•
The Inverter will detect overtorque when the current the same as or higher than the
detection level is output for the preset detection time.