3-7
D
Status Monitor
Item
Display
Display
unit
Function
U01
Frequency
reference
Hz
Monitors the frequency reference. (Same as FREF)
U02
Output
frequency
Hz
Monitors the output frequency. (Same as FOUT)
U03
Output current
A
Monitors the output current. (Same as IOUT)
U04
Output voltage
V
Monitors the internal output voltage reference value
of the Inverter.
U05
DC bus voltage
V
Monitors the DC voltage of the internal main circuit of
the Inverter.
U06
Input terminal
t t
---
Shows the ON/OFF status of inputs.
U06
put te
a
status
: Input ON
: No input
Not
used
Terminal S1: Forward/Stop
Terminal S2: Multi-function input 1 (S2)
Terminal S3: Multi-function input 2 (S3)
Terminal S4: Multi-function input 3 (S4)
Terminal S5: Multi-function input 4 (S5)
U07
Output terminal
---
Shows the ON/OFF status of outputs.
U0
Output te
a
status
: Closed
: Open
Not
used
Terminal MA: Multi-function
contact output
U09
Error log (most
t
)
---
Displays the latest error.
U09
o og ( ost
recent one)
Error
U10
Software No.
---
OMRON use only.
Preparing for Operation and Monitoring
Chapter 3
Summary of Contents for SYSDRIVE 3G3JV-AB001
Page 1: ...USER S MANUAL FIRST DRAFT SYSDRIVE 3G3JV Compact Simplified Inverter Cat No I528 E1 1...
Page 3: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Page 9: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 43: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Page 52: ...3 10 Preparing for Operation and Monitoring Chapter 3...
Page 53: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 62: ...4 10 Test Run Chapter 4...
Page 131: ...7 22 Maintenance Operations Chapter 7...
Page 132: ...Chapter 8 Specifications 8 1 Inverter Specifications 8 2 Option Specifications 8...
Page 138: ...Chapter 9 List of Parameters 9...
Page 150: ...Chapter 10 Using the Inverter for a Motor 10...
Page 165: ...Revision History 10 2...
Page 166: ...Cat No I528 E1 1 SYSDRIVE 3G3JV Compact Simplified Inverter USER S MANUAL...